![Brother HL-L8250CDN Скачать руководство пользователя страница 99](http://html.mh-extra.com/html/brother/hl-l8250cdn/hl-l8250cdn_service-manual_53705099.webp)
2-76
Confidential
■
Error code D800
Error occurred during touch panel initialization.
Error code D900
Communication between the panel PCB and main PCB is unavailable during touch panel
initialization.
Error code DA00
After the initialization of the panel PCB, no response was sent from the panel PCB for a period
of time.
Error code DB00
USB communication between the main PCB and panel PCB is unavailable.
Touchscreen initialization failed
Remove any material which is on the touchscreen.
-
-
-
-
-
-
Step
Cause
Remedy
1
The version of the panel
firmware and the main firmware
do not match
Install the latest panel firmware and main
firmware.
2
Connection failure of the key
PCB flat cable
Reconnect the key PCB flat cable.
3
Key PCB flat cable failure
Replace the key PCB flat cable.
4
Panel control PCB failure
Replace the panel control PCB ASSY.
5
LCD unit failure
Replace the LCD panel ASSY.
6
Key PCB failure
Replace the panel case ASSY.
7
Main PCB failure
Replace the main PCB ASSY.