![Brother HL-L8250CDN Скачать руководство пользователя страница 68](http://html.mh-extra.com/html/brother/hl-l8250cdn/hl-l8250cdn_service-manual_53705068.webp)
2-45
Confidential
■
Error code 0E00
Communication error occurred in the high-voltage power supply PCB ASSY.
■
Error code 1003
The registration mark sensor R is dirty and cannot normally receive reflected light.
< User Check >
- Clean the dirt on the belt unit or replace the belt unit.
- Replace the waste toner box.
■
Error code 1004
The registration mark sensor L is dirty and cannot normally receive reflected light.
< User Check >
- Clean the dirt on the belt unit or replace the belt unit.
- Replace the waste toner box.
Print Unable 0E
Turn the power off and then back on again.
Step
Cause
Remedy
1
Connection failure of the
high-voltage power supply PCB
harness
Reconnect the high-voltage power supply
PCB harness.
2
High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
Print Unable 10
Turn the power off and then back on again.
Step
Cause
Remedy
1
Dirt on the registration mark
sensor R
Clean the registration mark sensor R of
the registration mark sensor R PCB.
2
Dirt by toner inside the machine
Clean inside of the machine.
3
Registration mark sensor R PCB
failure
Replace the registration mark sensor unit.
4
Main PCB failure
Replace the main PCB ASSY.
Print Unable 10
Turn the power off and then back on again.
Step
Cause
Remedy
1
Dirt on the registration mark
sensor L
Clean the registration mark sensor L of
the registration mark sensor L PCB.
2
Dirt by toner inside the machine
Clean inside of the machine.
3
Registration mark sensor L PCB
failure
Replace the registration mark sensor unit.
4
Main PCB failure
Replace the main PCB ASSY.