![Brother HL-L8250CDN Скачать руководство пользователя страница 333](http://html.mh-extra.com/html/brother/hl-l8250cdn/hl-l8250cdn_service-manual_53705333.webp)
5-50
Confidential
1.3.25 Operational check of fans (Function code 78)
<Function>
This function is used to check that each fan is operating normally. The rotation speed is
changed among three settings: 100%, 50% and OFF.
<Operating procedure>
■
Location of fans
Fig. 5-17
LCD
Parts name
Description
F
Fuser fan
Evacuate hot air of the fuser unit.
P
Power fan
Evacuate hot air of the low-voltage power supply
PCB unit.
B
Blower
Intake air to prevent a dirt on the corona wire.
Model without touch panel
Model with touch panel
(1) Press the
or
key to display
“MAINTENANCE 78” on the LCD in the
initial state of the maintenance mode.
Then, press the
OK
key. “F100 P100
B100” is displayed on the LCD, and all
the fans operate at the rotating speed
of 100%.
(2) Press the
Go
key. “F50 P 0 B 0” is
displayed on the LCD, and the fuser fan
only operates at the rotating speed of
50%.
(3) Press the
Go
key. “F0 P 0 B 0” is
displayed on the LCD, and all the fans
stop.
(4) Press the
Cancel
key to return the
machine to the initial state of the
maintenance mode.
(1) Press the
7
and
8
keys in this order in
the initial state of the maintenance
mode. “F100 P100 B100” is displayed
on the LCD, and all the fans operate at
the rotating speed of 100%.
(2) Press the
Mono
key. “F50 P 0 B 0” is
displayed on the LCD, and the fuser fan
only operates at the rotating speed of
50%.
(3) Press the
Mono
key. “F0 P 0 B 0” is
displayed on the LCD, and all the fans
stop.
(4) Press the
X
key to return the machine
to the initial state of the maintenance
mode.
Fuser fan
Power fan
Blower