3-160
Confidential
(3) Loosen each clamp, release the TT balance sensor R harness from the securing
fixtures, and disconnect it from the TT balance sensor R relay harness.
(4) Remove the taptite cup S M3x8 SR screw to remove the attach sensor holder.
(5) Release the two hooks to remove the TT balance sensor R from the attach sensor
holder.
Fig. 3-156
Harness routing: Refer to
.
Assembling Note:
• Do not pull the TT balance sensor R relay harness too much, it may cause a
connection failure with the TT control PCB ASSY.
• When wiring, make sure that the TT balance sensor R harness does not come out
of the air duct.
Attach sensor holder
Taptite cup S M3x8 SR
Hooks
TT balance
sensor R
Clamps
TT balance sensor
R harness
TT balance sensor R
relay harness
Air duct
Содержание HL-5580D