3-36
Confidential
<Location of the leser beam window>
Fig. 3-6
■
Faulty registration
■
Dark
<User Check>
- Check that the appropriate media type is selected in the
printer driver.
Step
Cause
Check
Result
Remedy
1
Registration rear
actuator catching
on some position
Does the registration
rear actuator move
smoothly?
No
Re-assemble the
registration rear actuator.
2
Drum unit failure
Is the rotation torque of
the drum unit heavy?
Yes
Replace the drum unit.
<User Check>
- Check the machine's environment. High temperature and high
humidity conditions can cause this problem.
- Replace the drum unit with a new one.
- Replace the toner cartridge with a new one.
Step
Cause
Check
Result
Remedy
1
Drum unit
electrode dirty
Is the electrode of the
drum unit dirty?
Yes
Clean the electrode.
2
Drum unit failure
Is the problem solved
after replacing the drum
unit?
Yes
Replace the drum unit.
3
Developing bias
malfunciton
Is the problem solved
after reseting the
developer roller
counter?
Yes
Reset the developer roller
counter.
4
HVPS PCB
failure
Is the problem solved
after replacing the
HVPS PCB ASSY?
Yes
Replace the HVPS PCB
ASSY.
5
Main PCB failure
Is the problem solved
after replacing the main
PCB ASSY?
Yes
Replace the main PCB
ASSY.
Содержание HL 5370DW
Страница 12: ...CHAPTER 1 SPECIFICATIONS ...
Страница 32: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Страница 57: ...Confidential CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 109: ...Confidential CHAPTER 4 PERIODIC MAINTENANCE ...
Страница 129: ...4 19 Confidential 14 Secure the Fuser unit with the pan B M4x20 Taptite screw Fig 4 27 Taptite pan B M4x20 Fuser unit ...
Страница 145: ...CHAPTER 5 DISASSEMBLY REASSEMBLY ...
Страница 153: ...5 6 Confidential Fig 5 3 EM D110 4 places Separation pad ASSY ...
Страница 154: ...5 7 Confidential 5 GEAR LAYOUT DRAWING Fig 5 4 ...
Страница 187: ...5 40 Confidential 2 Remove the SW key B from the Top cover printed ASSY Fig 5 41 SW key B Top cover printed ASSY ...
Страница 200: ...5 53 Confidential 8 13 Main Shield Plate ASSY 1 Remove the Insulation sheet Fig 5 63 Insulation sheet Frame L ...
Страница 212: ...5 65 Confidential 8 24 Gear 17 20 23 1 Remove the Gear 23 Fig 5 84 2 Remove the Gear 20 Fig 5 85 ...
Страница 213: ...5 66 Confidential 3 Remove the Gear 17 black Fig 5 86 4 Remove the Gear 17 white Fig 5 87 ...
Страница 261: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 276: ...Confidential CHAPTER 7 SERVICE MODE ...
Страница 308: ...App 1 1 Confidential FIRMWARE SWITCHES WSW There is not function of the firmware switch in this machine ...