3-1
Confidential
1. INTRODUCTION
Troubleshooting is the countermeasure procedures that the service personnel should follow
if an error or malfunction occurs with the machine. It is impossible to anticipate all of the
possible troubles which may occur in future and determine the troubleshooting procedures,
so this chapter covers some sample troubles. However, those samples will help the service
personnel pinpoint and repair other defective elements.
1.1
Precautions
Be sure to observe and follow all the precautions to prevent any secondary problems from
happening during troubleshooting.
(1) Always turn off the power and unplug the power cable before removing any covers or
PCBs, adjusting the machine and so on. If you need to take voltage measurements with
the power switched on, take the greatest of care not to receive an electric shock.
(2) When connecting or disconnecting cable connectors, make sure that you hold the
connector body and not the cables.
(3) Electronic devices are sensitive to static build up; make sure that you touch a metal
portion of the machine to discharge yourself before accessing the PCBs.
Handle PCBs with care when repairing them.
(4) Follow the warning by all means.
(5) Verify again that the repaired portion works properly.
warning
The fuser unit becomes extremely hot during operation. Wait until it has cooled down
sufficiently before replacing consumable items. DO NOT remove or damage the
caution label located on or around the fuser.
Содержание HL 5370DW
Страница 12: ...CHAPTER 1 SPECIFICATIONS ...
Страница 32: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Страница 57: ...Confidential CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 109: ...Confidential CHAPTER 4 PERIODIC MAINTENANCE ...
Страница 129: ...4 19 Confidential 14 Secure the Fuser unit with the pan B M4x20 Taptite screw Fig 4 27 Taptite pan B M4x20 Fuser unit ...
Страница 145: ...CHAPTER 5 DISASSEMBLY REASSEMBLY ...
Страница 153: ...5 6 Confidential Fig 5 3 EM D110 4 places Separation pad ASSY ...
Страница 154: ...5 7 Confidential 5 GEAR LAYOUT DRAWING Fig 5 4 ...
Страница 187: ...5 40 Confidential 2 Remove the SW key B from the Top cover printed ASSY Fig 5 41 SW key B Top cover printed ASSY ...
Страница 200: ...5 53 Confidential 8 13 Main Shield Plate ASSY 1 Remove the Insulation sheet Fig 5 63 Insulation sheet Frame L ...
Страница 212: ...5 65 Confidential 8 24 Gear 17 20 23 1 Remove the Gear 23 Fig 5 84 2 Remove the Gear 20 Fig 5 85 ...
Страница 213: ...5 66 Confidential 3 Remove the Gear 17 black Fig 5 86 4 Remove the Gear 17 white Fig 5 87 ...
Страница 261: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 276: ...Confidential CHAPTER 7 SERVICE MODE ...
Страница 308: ...App 1 1 Confidential FIRMWARE SWITCHES WSW There is not function of the firmware switch in this machine ...