7-13
Confidential
21) Developer Roller Counter Reset 1 (Ineffective)
21) Developer Roller Counter Reset 2 (For the standard toner cartridge)
21) Developer Roller Counter Reset 3 (For the high-capacity toner cartridge)
Since print density is likely to become darker as toner is getting older, the developing
bias is lowered by degrees according to the number of prints so that an almost fixed
density can be maintained from the start of the use of brand-new toner to the end of it.
The value of the developing bias is printed on the maintenance sheet. The developing
bias is a parameter which depends on the developing assembly, so it needs to be reset
when the developing assembly is replaced. At that time, the developing roller counter
reading is also reset. This mode is to enable to execute these operations (equivalent to
those done when the developing assembly is replaced) manually from the service
mode.
22) Fixed USB Speed Mode
This allows you to switch the setting of Full fixed/Auto switching (HIGH/FULL) of the
USB speed. Whenever switching, the current setting is changed to the other one.
The default setting is Auto switching.
It also allows you to check the selected setting by the
Toner
LED (Full fixed) or
Drum
LED (Auto switching) being lit for 1 second when releasing the [Go] button.
LED Model
LCD Model
When switch the
setting from Auto
switching to Full
fixed.
Toner LED lights
for 1 second.
Data LED is
OFF.
When switch the
setting from Full
fixed to Auto
switching.
Drum LED lights
for 1 second.
Data LED is ON.
Back
Cover
Toner
Drum
Paper
Status
Back
Cover
Toner
Drum
Paper
Status
Содержание HL 5370DW
Страница 12: ...CHAPTER 1 SPECIFICATIONS ...
Страница 32: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Страница 57: ...Confidential CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 109: ...Confidential CHAPTER 4 PERIODIC MAINTENANCE ...
Страница 129: ...4 19 Confidential 14 Secure the Fuser unit with the pan B M4x20 Taptite screw Fig 4 27 Taptite pan B M4x20 Fuser unit ...
Страница 145: ...CHAPTER 5 DISASSEMBLY REASSEMBLY ...
Страница 153: ...5 6 Confidential Fig 5 3 EM D110 4 places Separation pad ASSY ...
Страница 154: ...5 7 Confidential 5 GEAR LAYOUT DRAWING Fig 5 4 ...
Страница 187: ...5 40 Confidential 2 Remove the SW key B from the Top cover printed ASSY Fig 5 41 SW key B Top cover printed ASSY ...
Страница 200: ...5 53 Confidential 8 13 Main Shield Plate ASSY 1 Remove the Insulation sheet Fig 5 63 Insulation sheet Frame L ...
Страница 212: ...5 65 Confidential 8 24 Gear 17 20 23 1 Remove the Gear 23 Fig 5 84 2 Remove the Gear 20 Fig 5 85 ...
Страница 213: ...5 66 Confidential 3 Remove the Gear 17 black Fig 5 86 4 Remove the Gear 17 white Fig 5 87 ...
Страница 261: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 276: ...Confidential CHAPTER 7 SERVICE MODE ...
Страница 308: ...App 1 1 Confidential FIRMWARE SWITCHES WSW There is not function of the firmware switch in this machine ...