3.2 Cleaning the Corona Wire
!
CAUTION:
It is recommended to place the drum/toner ASSY on a piece of disposable paper or cloth in
case you accidentally spill or scatter toner.
If you have print quality problems, clean the corona wire as follows:
(1) Press the front cover release button and then open the front cover.
Fig. 3-89
(2) Take out the drum unit and toner cartridge assembly.
Fig. 3-90