![Brother FAX-2950 Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/brother/fax-2950/fax-2950_service-manual_20837091.webp)
2-54
Confidential
Error code D2 to DC
These errors do not usually occur in the normal use. The conceivable causes are noise
around the installation site, fluctuation of the power supply voltage, and failures in the
software.
An unidentified error occurred.
Error code DD
Fuser unit error (except error codes 6A to 6E, 76, 78, DE and E2)
---
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Print Unable DD
See Troubleshooting and routine maintenance chapter in User's Guide.
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
Cause
Remedy
1
Connection failure of the fuser
unit harnesses
Reconnect the fuser unit harnesses.
2
Connection failure of the eject
sensor PCB harness
Reconnect the eject sensor PCB harness.
3
Eject sensor PCB failure
Replace the eject sensor PCB ASSY.
4
Low voltage power supply PCB
failure
Replace the low voltage power supply PCB
ASSY.
5
Main PCB failure
Replace the main PCB ASSY.
6
Fuser unit failure
Replace the fuser unit.
Содержание FAX-2950
Страница 20: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Страница 35: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Страница 45: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 ...
Страница 122: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Страница 130: ...3 6 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Страница 136: ...3 12 Confidential 3 New toner sensor PCB ASSY New toner sensor PCB ASSY Main PCB ASSY Guide ...
Страница 140: ...3 16 Confidential 8 Main fan High voltage power supply PCB ASSY Guide Main fan Tape Hole of guide Hole of guide ...
Страница 143: ...3 19 Confidential 12 Speaker unit Guide Speaker harness Guide Guides Guides Speaker unit Main PCB ASSY ...
Страница 153: ...3 29 Confidential 9 3 Cord hook 1 Turn the two cord hooks and then remove them from the machine Fig 3 12 Cord hooks ...
Страница 204: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 217: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Страница 224: ...5 5 Confidential Black and white color scanning Fig 5 1 ...
Страница 263: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Страница 266: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 267: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL REPLACEMENT PARTS 7 1 ...
Страница 268: ...7 1 Confidential 1 PERIODICAL REPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 269: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Страница 273: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...
Страница 275: ...Confidential APPENDIX 4 HOW TO MAKE PROTECTIVE MATERIAL FOR DRUM UNIT ...