2-33
Confidential
Error code 6A
The center thermistor of the fuser unit does not reach the specified temperature within the
specified time.
Error code 6B
The center thermistor of the fuser unit does not reach the specified temperature within the
specified time.
Error code 6C
The center thermistor of the fuser unit detected a temperature higher than the specified value.
Error code 6D
After the heat unit was heated normally, the center thermistor of the fuser unit detected a
temperature lower than the specified value.
Error code 6E
This error does not usually occur in the normal use. The conceivable causes are noise
around the installation site, fluctuation of the power supply voltage, and failures in the
software.
An unidentified error occurred.
Print Unable 6A
Turn the power off and then back on again.
Print Unable 6B
Turn the power off and then back on again.
Print Unable 6C
Turn the power off and then back on again.
Print Unable 6D
Turn the power off and then back on again.
Step
Cause
Remedy
1
Connection failure of the fuser
unit harness
Reconnect the fuser unit harness.
2
Fuser unit failure
Replace the fuser unit.
3
Low voltage power supply PCB
failure
Replace the low voltage power supply PCB
ASSY.
4
Eject sensor PCB failure
Replace the eject sensor PCB ASSY.
5
Main PCB failure
Replace the main PCB ASSY.
---
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Содержание FAX-2950
Страница 20: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Страница 35: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Страница 45: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 ...
Страница 122: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Страница 130: ...3 6 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Страница 136: ...3 12 Confidential 3 New toner sensor PCB ASSY New toner sensor PCB ASSY Main PCB ASSY Guide ...
Страница 140: ...3 16 Confidential 8 Main fan High voltage power supply PCB ASSY Guide Main fan Tape Hole of guide Hole of guide ...
Страница 143: ...3 19 Confidential 12 Speaker unit Guide Speaker harness Guide Guides Guides Speaker unit Main PCB ASSY ...
Страница 153: ...3 29 Confidential 9 3 Cord hook 1 Turn the two cord hooks and then remove them from the machine Fig 3 12 Cord hooks ...
Страница 204: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 217: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Страница 224: ...5 5 Confidential Black and white color scanning Fig 5 1 ...
Страница 263: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Страница 266: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 267: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL REPLACEMENT PARTS 7 1 ...
Страница 268: ...7 1 Confidential 1 PERIODICAL REPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 269: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Страница 273: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...
Страница 275: ...Confidential APPENDIX 4 HOW TO MAKE PROTECTIVE MATERIAL FOR DRUM UNIT ...