V –
24
WSW12
(Signal detection condition setting)
Selector
No.
Function
Setting and Specifications
7
8
Delay
Not used.
5
6
No. 5
6
0
0
:
800 ms (1000 ms*)
0
1
:
200 ms
1
0
:
250 ms
1
1
:
150 ms
Detecting time setting
3
4
Max. OFF time length of calling
signal (Ci)
No. 3
4
0
0
:
6 sec.
0
1
:
7 sec.
1
0
:
9 sec.
1
1
:
11 sec.
1
2
Min. OFF time length of calling
signal (Ci)
No. 1
2
0
0
:
300 ms
0
1
:
500 ms
1
0
:
700 ms
1
1
:
900 ms
* 1000 ms in Chinese or Hong Kong versions.
●
Selectors 1 through 4:
Min. and max. OFF time length of calling signal (Ci)
If the equipment detects the OFF state of calling signal (Ci) for a time length which is greater
than the value set by selectors 1 and 2 and less than the value set by selectors 3 and 4, it
interprets the Ci signal as OFF.
●
Selectors 5 and 6: Detecting time setting
These selectors set the time length required to make the equipment acknowledge itself to be
called. That is, if the equipment continuously detects calling signals with the frequency set
by selectors 1 through 4 of WSW14 during the time length set by these selectors 5 and 6, it
acknowledges the call.
●
Selector 7:
Delay
Setting this selector to "0" allows the equipment to insert a 900 ms WAIT after
acknowledgement of the call until the equipment turns on the CML relay to start receiving
operation.
0:
Yes
1:
No
Содержание FAX-270MC
Страница 4: ...CHAPTER I GENERAL DESCRIPTION ...
Страница 11: ...CHAPTER II INSTALLATION ...
Страница 12: ...CHAPTER III THEORY OF OPERATION ...
Страница 49: ...CHAPTER IV DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Страница 86: ...IV 36 4 Cutter unit Cutter unit A A A A ...
Страница 87: ...CHAPTER V MAINTENANCE MODE ...
Страница 140: ...CHAPTER VI ERROR INDICATION AND TROUBLESHOOTING ...
Страница 157: ...March 98 5X1S112 Printed in Japan ...
Страница 173: ...D POWER SUPPLY 100 120 V U S A CANADA ...
Страница 174: ...POWER SUPPLY 200 240 V EUROPE SOUTH AMERICA D ...
Страница 175: ...POWER SUPPLY 200 240 V GULF ASIA CHINA D ...
Страница 192: ...D POWER SUPPLY 100 120 V U S A CANADA ...
Страница 193: ...POWER SUPPLY 200 240 V EUROPE SOUTH AMERICA D ...
Страница 194: ...POWER SUPPLY 200 240 V GULF ASIA CHINA D ...
Страница 195: ...FACSIMILE EQUIPMENT PARTS REFERENCE LIST MODEL FAX170 190 190 Plus 195 ...
Страница 198: ......
Страница 203: ......
Страница 206: ...Remarks 8 8 8 8 8 8 9 9 8 8 8 8 8 8 0 1 0 1 Brother Technical Information FAX98250 4 ...
Страница 208: ... 8 01 8 01 8 8 8 8 0 1 0 1 8 8 8 8 Brother Technical Information FAX99102 6 ...
Страница 220: ......