5-67
Confidential
1.3.35 Developing bias voltage correction (Function code 83)
<Function>
This function performs developing bias voltage correction to fix the density of each color toner
when printed color is not correct.
<Operating procedure>
(1) Press the
8
and
3
keys in this order in the initial state of the maintenance mode.
The machine displays “PLS WAIT 83” on the LCD and starts the developing bias voltage
correction.
(2) When developing bias voltage correction is completed, “MODE KYMC ****” is displayed
on the LCD. When you press the
Mono Start
key, the machine returns to the initial state
of the maintenance mode.
(* represents any number from 0 to 3.)
* # indicates the toner color (Y, M, or C) of which cartridge became empty.
Note:
Before this function is performed, there is a need that the
“1.3.28 Sensitivity adjustment of
density sensor (Function code 72)” in this chapter
has been done more than once. When
performing this maintenance mode 83 after replacing the main PCB ASSY, make sure to
perform the
“1.3.28 Sensitivity adjustment of density sensor (Function code 72)”
first.
Note:
If developing bias voltage correction fails, “ERROR 83” is displayed on the LCD. Display the
error message by pressing the
key, and take the following measure that corresponds to
the error message.
Error message
Measure
FAILED DEVBIAS
Remove the error factors with the following operations and press the
Mono Start
key to clear the error.
- Re-insert the toner cartridge in the correct position.
- Replace the toner cartridge.
- Replace the drum unit.
- Replace the waste toner box.
- Replace the belt unit.
- Replace the registration mark sensor unit.
TONER EMPTY #
*
Replace the empty toner cartridge and press the
Mono Start
key to
clear the error. After the sensitivity adjustment of the density sensor
(
) is performed, the developing bias voltage value
is compensated again.
Cover is Open
Close the front cover.
Replace Toner
Replace the black toner cartridge and press the
Mono Start
key to
clear the error. After the sensitivity adjustment of the density sensor
(
) is performed, the developing bias voltage value
is compensated again.
Содержание DCP-L8400CDN
Страница 38: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 Right side Left side Face up Document scanning feed path ...
Страница 249: ...3 85 Confidential 3 Remove the ADF spring from the Upper ADF chute Fig 3 95 ADF spring Upper ADF chute ...
Страница 277: ...3 113 Confidential 9 35 LCD 1 Remove the LCD from the Control panel ASSY Fig 3 145 Control panel ASSY LCD ...
Страница 391: ...5 7 Confidential Common to first and second side Fig 5 1 ...