3-163
Confidential
9.62 Low-voltage Power Supply PCB Unit
(1) Remove the Screw pan (S/P washer) M3.5x6 screw and remove the FG harness of the
Inlet harness ASSY from the LVPS plate.
(2) Remove the Taptite flat B M3x10 screw and remove the Inlet harness ASSY from the
Main body.
(3) Release the wiring of the Inlet harness ASSY.
(4) Release the wiring of the LVPS-heater harness ASSY.
Fig. 3-229
Screw pan
Inlet harness ASSY
Main body
(S/P washer) M3.5x6
Taptite flat B M3x10
<Back side>
LVPS plate
Inlet harness ASSY
FG harness of the