![Brother DCP-L5500D Скачать руководство пользователя страница 278](http://html.mh-extra.com/html/brother/dcp-l5500d/dcp-l5500d_service-manual_53476278.webp)
3-118
Confidential
9.44 Paper empty sensor PCB ASSY
(Models with USB host on the rear side only)
(1) Release the hook on the bushing, and pull out the separation roller shaft to remove the
paper empty actuator.
(2) Release the hook, and remove the paper empty actuator cover.
(3) Remove the taptite bind B M3x10 screw, and remove the paper empty sensor PCB
ASSY. Disconnect the paper empty sensor harness from the paper empty sensor PCB
ASSY, and release the paper empty sensor harness from the securing fixtures.
Fig. 3-119
Harness routing: Refer to
“12. Bottom side of the machine”
.
Paper empty actuator
Paper empty
actuator cover
Paper empty sensor PCB ASSY
Separation roller shaft
Hook
Taptite bind B M3x10
Paper empty sensor harness
Bushing
Hook