2-99
Confidential
■
Error code A700
Color parameter in the ROM does not match the first side or second side CIS.
Error code A900
A scanning error occurred while processing the scanned image.
■
Error code AC00
When scanning the fax, white or black correction data for the second side CIS was not within
the correct range (first time).
■
Error code AD00
Image processing cannot be completed correctly because the number of pixels required for
image processing is insufficient in the scanned first side data.
Step
Cause
Remedy
1
Incorrect correction data for first
side or second side CIS unit
Execute “Set CIS scan area (
)”.
2
Damaged first side CIS flat cable
Replace the first side CIS flat cable.
3
Damaged second side CIS flat
cable
Replace the second side CIS flat cable.
4
First side CIS unit failure
Replace the first side CIS unit.
5
Second side CIS unit failure
Replace the second side CIS unit.
6
Main PCB failure
Replace the main PCB.
Step
Cause
Remedy
1
Incorrect correction data for
second side CIS unit
Execute “Acquire white level data
(
)”.
2
Dirt on the white tape on the
second side document hold
Clean the white tape on the second side
document hold.
3
Damaged second side CIS flat
cable
Replace the second side CIS flat cable.
4
Second side CIS unit failure
Replace the second side CIS unit.
5
White tape failure
Replace the ADF unit.
6
Main PCB failure
Replace the main PCB.
Step
Cause
Remedy
1
Incorrect correction data for first
side CIS unit
Execute “Set CIS scan area (
)”.
2
Connection failure of the first
side CIS flat cable
Reconnect the first side CIS flat cable.
3
First side CIS unit failure
Replace the first side CIS unit.
4
White tape failure
Replace the document scanner unit.
5
Main PCB failure
Replace the main PCB.
Содержание DCP-L3510CDW
Страница 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Страница 50: ...2 14 Confidential Fig 2 8 Document scanning position sensor Document detection sensor ADF cover sensor ...
Страница 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Страница 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Страница 203: ...3 12 Confidential 4 Lower document chute Flat core Second side CIS flat cable Lower document chute ...
Страница 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Страница 212: ...3 21 Confidential 13 High voltage power supply flat cable High voltage power supply flat cable ...
Страница 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Страница 228: ...3 37 Confidential 9 6 Cord hook 1 Remove the Cord hook Two locations Fig 3 15 Cord hooks Cord hook Back side ...
Страница 347: ...5 19 Confidential Fig 5 7 Document scanning position sensor Document detection sensor ADF cover sensor ...
Страница 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...