![Brother DCP-L3510CDW Скачать руководство пользователя страница 101](http://html.mh-extra.com/html/brother/dcp-l3510cdw/dcp-l3510cdw_service-manual_53471101.webp)
2-65
Confidential
■
Error code 0900
Detected irregular power supply for more than 100 times.
<User Check>
• Turn OFF the power switch. After several seconds, turn ON the power again and check that
this error is reset.
■
Error code 0A02
Main PCB detected the fan failure.
Step
Cause
Remedy
1
Low-voltage power supply PCB
failure
Replace the low-voltage power supply
PCB. Refer to
consumable parts (Function code 88)” in
Chapter 5
to reset the irregular power
supply detection counter after the
replacement.
2
Main PCB failure
Replace the main PCB.
Note:
The irregular power supply detection error (Error code 0900) of the low-voltage power
supply PCB occurs when there is a large distortion in the power supply voltage supplied to
the machine. In this case, if the same power supply is used, the same error might occur
again even if the low-voltage power supply PCB is replaced. For this reason, be sure to ask
the user to rearrange the installation environment.
Step
Cause
Remedy
1
Connection failure of the fan
harness
Reconnect the fan harness.
2
Connection failure of the high-
voltage power supply flat cable
Reconnect the high-voltage power supply
flat cable.
3
Fan failure
Replace the fan.
4
High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB.
5
Main PCB failure
Replace the main PCB.
Содержание DCP-L3510CDW
Страница 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Страница 50: ...2 14 Confidential Fig 2 8 Document scanning position sensor Document detection sensor ADF cover sensor ...
Страница 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Страница 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Страница 203: ...3 12 Confidential 4 Lower document chute Flat core Second side CIS flat cable Lower document chute ...
Страница 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Страница 212: ...3 21 Confidential 13 High voltage power supply flat cable High voltage power supply flat cable ...
Страница 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Страница 228: ...3 37 Confidential 9 6 Cord hook 1 Remove the Cord hook Two locations Fig 3 15 Cord hooks Cord hook Back side ...
Страница 347: ...5 19 Confidential Fig 5 7 Document scanning position sensor Document detection sensor ADF cover sensor ...
Страница 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...