4.14.3 Machine is not turned ON
<User Check>
- Check that the power cord is inserted into the terminal correctly.
- Turn the power off and on.
Step
Cause
Remedy
1
Rubber key attachment failure
(For models without touch panel)
Reattach the rubber key.
2
Connection failure of panel harness Reconnect the panel harness.
3
Connection failure of key PCB flat
cable (For models with touch panel)
Reconnect the key PCB flat cable.
4
Connection failure of LCD flat cable Reconnect the LCD flat cable.
5
Connection failure of LVPS harness Reconnect the LVPS harness.
6
Power cord failure
Replace the power cord.
7
Panel PCB failure
Replace the panel PCB.
8
LCD failure
Replace the LCD.
9
Low-voltage power supply PCB
failure
Replace the low-voltage power supply PCB
ASSY.
10
Main PCB failure
Replace the main PCB ASSY.