2-96
Confidential
Downward fogging of solid color
Horizontal lines
<User Check>
• Replace the toner cartridge with a new one.
Step
Cause
Remedy
1
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
2
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• This problem may disappear after printing multiple
sheets of paper.
• Refer to
to remove the
dirt from the exposure drum using a cotton applicator.
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
Step
Cause
Remedy
1
Dirty charge electrodes
Clean the electrodes of the drum unit and
those of the machine. (Refer to
2
Dirt on the exposure drum
Perform drum cleaning.
(Refer to
“2.1 Drum Cleaning” in Chapter 5
3
Scratch or dirt on the fuser
unit
Replace the fuser unit.
4
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...