2-93
Confidential
Spots or dirt
<User Check>
• Check if damp paper is used.
• Refer to
to remove the dirt from the
exposure drum using a cotton applicator.
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
Step
Cause
Remedy
1
Dirt on the paper dust
cleaning roller of the paper
tray
Refer to the
to clean the
paper dust cleaning roller.
2
Dirt on the exposure drum
Perform drum cleaning.
(Refer to
“2.1 Drum Cleaning” in Chapter 5
3
Clogged filter
Clean the filter.
4
Scratch or dirt on the fuser
unit
Replace the fuser unit.
5
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
Note:
Image defects which appear periodically may be caused by failure of rollers. Refer to
<Pitches on images caused by rollers>
and determine the cause based on the pitch at
which defects appear on the image.
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...