background image

 Warranty

This appliance must be installed and commissioned by a fully qualified, registered engineer. A “Declaration of completion 
Certificate” must be obtained for the installation and retained by the end user. Failure to comply with these requirements 
may void your warranty.
You, as the end user, have a contract by law with the supplier / dealer from whom you purchased the product. That 
dealer then has the same contract with the manufacturer or wholesaler and these have a contract with their suppliers. 

ALL CLAIMS MUST FOLLOW THIS PROCEDURE.

Thank you for choosing a Product from 

Broseley Fires Ltd

. This warranty gives you specific legal rights. The statutory 

rights of the consumer are not affected by the warranty, or the consumers’ rights against the dealer arising from their 
sales / purchase contract.

The manufacturers’ warranty: 

Your Product will be free from defective parts, material, and workmanship at the time of its original purchase for a period 
of two (2) years. This Warranty will become active as of one month from the date of delivery.

This warranty does not cover any failure of the unit due to normal wear and tear, misuse, abuse, accident, illegal 
modification, illegal installation or repair, damage resulting from improper use or failure to maintain the product. 
Variations in color and texture are a natural characteristic of cast iron products. Colour changes may result from 
exposure to light and other elements which are a part of the aging process. These material variations and changes are 
not covered by this warranty. If during the warranty period, this Product fails to operate under normal use and service, 
due to defects in material and / or workmanship, Broseley Fires will either repair or replace the product.The repaired or 
replaced product shall be warranted for the remaining period of the original wa the time taken to days from the 
date of repair, whichever is longer.

Repair or replacement may involve the use of functionally equivalent reconditioned units. Replaced parts or components 
will become the property of Broseley Fires. 

Should you wish to claim under the warranty, please contact the supplier / dealer from whom you purchased the 
appliance.  Do not claim directly to Broseley Fires, as they are unable to process any direct claim from an end user.

Product design and any specifications are subject to change without notice. This is due to our continuous product 
development and improvement. The buyer will not be entitled to request free upgrades to the new design or 
compensation for previously purchased products or any products on order. 

This Warranty covers all Broseley Fires costs within the Warranty period.

If the appliance remains uninstalled for a period greater than six months from date of delivery the Warranty will become 
active six months from the date of original invoice to the distributor.

I

N

 

NO

 

EVENT

 

SHALL

 B

ROSELEY

 F

IRES

 

BE

 

LIABLE

 

FOR

 

INCIDENTAL

 

OR

 

CONCEQUENTIAL

 

DAMAGES

 

OF

 

ANY

 

NATURE

 

WHATSOEVER

INCLUDING

 

BUT

 

NOT

 

LIMITED

 

TO

 

LOST

 

PROFITS

 

OR

 

COMMERCIAL

 

LOSS

TO

 

THE

 

FULL

 

EXTENT

 

THOSE

 

DAMAGES

 

CAN

 

BE

 

DISCLAIMED

 

BY

 

LAW

. (if applicable)

NON - COVERAGE OF THE GUARANTEE

The consumable items within the product are not covered by the warranty, nor is the glass
If the end-user’s claim should not be covered by this guarantee, the end-user shall be liable for costs incurred by 
Broseley Fires such as callout and inspection costs for examination of the product, transportation costs of the product as 
well as any other relevant costs. 
If, after having been informed about the non-coverage of the guarantee, the end-user wants to have the repairs done, the 
end-user shall additionally pay for any spare parts used and for the labour and transportation costs incurred. If repairs 
are carried out under this guarantee, the remaining guarantee period for the product shall be extended by the period of 
time that has elapsed since the complaint was officially logged with Broseley Fires until the repairs have been completed

A

 

COPY

 

OF

 

OUR

 

FULL

 

TERMS

 

AND

 

CONDITIONS

 

IS

 

AVAILABLE

 

ON

 

REQUEST

.

** End-user means the natural or legal person who owns the product and who has not acquired it with a view to reselling or installing it 
in the course of business

GB12A Issue 2

28

Содержание Silverdale 5

Страница 1: ...stallation Operating Instructions Covering Models Silverdale 5 7 Wood Burning Stoves Tested to EN 13240 These appliances must be installed and commissioned by a HETAS registered engineer GB12A Issue 2...

Страница 2: ...14 Ash Pan 14 Recommended Fuels 15 Lighting the Stove Kindling Stage 16 Burning Wood 17 Smoke Exempt Requirements 18 Lighting sequence in smoke controlled areas 19 Warning Notes 19 Maintenance Ash Re...

Страница 3: ...lation of the stove although detail may need slight modification to suit particular local site conditions In all cases the installation must comply with current Building Regulations Local Authority By...

Страница 4: ...e that whenever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwelling an audible carbon monoxide alarm must be fitted in the same room as the appliance Further gui...

Страница 5: ...logs only European standards need to be complied with when installing this appliance GB12A Issue 2 5 5 7 Efficiency 77 8 76 6 Weight Kg 42 53 Flue Diameter mm 125 125 Flue Diameter Inches 5 5 Flue Dra...

Страница 6: ...Dimensions ALL DIMENSIONS ARE IN MILIMETRES GB12A Issue 2 6...

Страница 7: ...must be fitted if the hearth is flush with the carpet These are just a few hearth specifications Please refer to Building Regulations Approved Document J Hearths for more specific details Clearances...

Страница 8: ...ey e g anti down draft cowl to eliminate wind induced down draft The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved...

Страница 9: ...ost eliminated by double glazing etc Under UK building regulations any appliance over 5kW MUST have a fixed permanent air vent see building regulations approved document J for further information Ther...

Страница 10: ...mbly Silverdale 5 The diagram below shows the stove with all internals taken out To install the internals simply follow the numbered sequence 1 9 and to remove simply reverse this process GB12A Issue...

Страница 11: ...y Silverdale 7 The diagram below shows the stove with all internal parts taken out To install the internals simply follow the numbered sequence 1 9 and to remove simply reverse this process GB12A Issu...

Страница 12: ...re that the operating instructions for the stove are left with the consumer Ensure to advise the customer on the correct use of the appliance and warn them to use only the recommended fuel for the sto...

Страница 13: ...need to be operated correctly to control the combustion rate of the stove Secondary Air Intake Primary Air Intake T The main door handle on these appliances will get hot but are removable To remove th...

Страница 14: ...e through left to right so the slider can control the total amount of air required for suitable combustion The secondary air intake brings in air above the grate this air is drawn down the inside of t...

Страница 15: ...e coating of soot and tar in the chimney is volatile creating a high risk of chimney fires A growing tree contains a high percentage of water the wood needs to be dried out seasoned before it is suita...

Страница 16: ...ndling onto the newspaper ensure their is sufficient air gaps between the kindling a criss cross or pyramid style pattern is ideal to accomplish this Kindling Newspaper Stage 2 Ignite the paper undern...

Страница 17: ...own the Secondary Air Intake as required You can now control the burn rate of the stove using the secondary air intake You are looking for a controlled flame not smouldering in the embers or licking a...

Страница 18: ...ster in the devolved administrations The Amalia Oppdal and Silverdale 5 7 has been recommended as suitable for use in smoke control areas when burning wood logs Further information on the requirements...

Страница 19: ...lead to over firing Over firing is caused when too much heat is generated within the fire chamber this will lead to warping buckling and general damage to the stove and its internal components Over fi...

Страница 20: ...is possible that the higher flue gas temperature from a closed appliance may loosen deposits that were previously firmly adhered with the consequent risk of flue blockage It is therefore recommended...

Страница 21: ...being drawn up the chimney to waste Green or wet wood is being burnt The chimney has excessive draw this is unusual Seek installer advice with regard to installing a Flue Draught Stabiliser The stove...

Страница 22: ...Address _________________________________________________________________ Telephone Inc area code ____________________________________________________ HETAS Registration Number _______________________...

Страница 23: ...10 Side Firebricks x2 11 Bottom Side Firebricks x2 12 Grate 13 Bottom Front Firebrick 14 Ash Pan 15 Fixings M5 16 M5 Washers 17 Latch 18 Slider 19 Handle Knob 20 Handle 21 Door 22 Knob 23 Hinge Pin 24...

Страница 24: ...2 10 Side Firebricks x2 11 Bottom Side Firebricks x2 12 Grate 13 Bottom Front Firebrick 14 Ash Pan 15 Fixings M5 16 M5 Washers 17 Latch 18 Slider 19 Handle Knob 20 Handle 21 Door 22 Knob 23 Hinge Pin...

Страница 25: ...S WAY BATTLEFIELD ENT PARK SHREWSBURY SY1 3AB ph 44 0 1743 461444 MANUFACTURER RRF Rhein Ruhr Feuerst tten Pr fstelle GmbH NOTIFIED BODY RRF 1625 Firmensitz Im Lipperfeld 34 b D 46047 Oberhausen The f...

Страница 26: ...S WAY BATTLEFIELD ENT PARK SHREWSBURY SY1 3AB ph 44 0 1743 461444 MANUFACTURER RRF Rhein Ruhr Feuerst tten Pr fstelle GmbH NOTIFIED BODY RRF 1625 Firmensitz Im Lipperfeld 34 b D 46047 Oberhausen The f...

Страница 27: ...DRESS POSTCODE 3RD YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POST...

Страница 28: ...or components will become the property of Broseley Fires Should you wish to claim under the warranty please contact the supplier dealer from whom you purchased the appliance Do not claim directly to B...

Отзывы: