background image

 EC Declaration

DECLARATION OF CONFORMITY

ACCORDING TO DIRECTIVES 89/106/EEC (CONSTRUCTION 

PRODUCTS) 

 

 

 

BROSELEY FIRES LTD 

KNIGHTS WAY, BATTLEFIELD ENT PARK. 

SHREWSBURY. SY1 3AB ph: +44 (0)1743 461444

ISSUED BY:

 

 

 

 

TYPE OF EQUIPMENT: 

 

WOOD BURNING STOVE

 

TRADEMARK:

 

BROSELEY FIRES LTD 

 

MODEL:

 SILVERDALE 

7

USE:

 

DOMESTIC SPACE HEATING

 

 

 

 

 

 

 

 

 

 

 

BROSELEY FIRES LTD 

KNIGHTS WAY, BATTLEFIELD ENT PARK. 

SHREWSBURY. SY1 3AB ph: +44 (0)1743 461444

MANUFACTURER:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RRF Rhein-Ruhr Feuerstätten Prüfstelle GmbH

NOTIFIED BODY:

RRF 1625  

Firmensitz

Im Lipperfeld 34 b 

D-46047 Oberhausen 

 

 

 

The following  harmonised standards and Technical specifications have been met and  comply 
with good engineering practice and safety matters in force within the EEC

All CE standards or other documents

   Innitial Type Test Reports         RRF-40 12 3143 

 

 

 

 

 

 

                

 

EN 13240

 

CE MARKING INFORMATION  

-  See Instructions

                   Particular/Smoke Conditions Exempt

 

 

 

GB12A Issue 2

26

Содержание Silverdale 5

Страница 1: ...stallation Operating Instructions Covering Models Silverdale 5 7 Wood Burning Stoves Tested to EN 13240 These appliances must be installed and commissioned by a HETAS registered engineer GB12A Issue 2...

Страница 2: ...14 Ash Pan 14 Recommended Fuels 15 Lighting the Stove Kindling Stage 16 Burning Wood 17 Smoke Exempt Requirements 18 Lighting sequence in smoke controlled areas 19 Warning Notes 19 Maintenance Ash Re...

Страница 3: ...lation of the stove although detail may need slight modification to suit particular local site conditions In all cases the installation must comply with current Building Regulations Local Authority By...

Страница 4: ...e that whenever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwelling an audible carbon monoxide alarm must be fitted in the same room as the appliance Further gui...

Страница 5: ...logs only European standards need to be complied with when installing this appliance GB12A Issue 2 5 5 7 Efficiency 77 8 76 6 Weight Kg 42 53 Flue Diameter mm 125 125 Flue Diameter Inches 5 5 Flue Dra...

Страница 6: ...Dimensions ALL DIMENSIONS ARE IN MILIMETRES GB12A Issue 2 6...

Страница 7: ...must be fitted if the hearth is flush with the carpet These are just a few hearth specifications Please refer to Building Regulations Approved Document J Hearths for more specific details Clearances...

Страница 8: ...ey e g anti down draft cowl to eliminate wind induced down draft The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved...

Страница 9: ...ost eliminated by double glazing etc Under UK building regulations any appliance over 5kW MUST have a fixed permanent air vent see building regulations approved document J for further information Ther...

Страница 10: ...mbly Silverdale 5 The diagram below shows the stove with all internals taken out To install the internals simply follow the numbered sequence 1 9 and to remove simply reverse this process GB12A Issue...

Страница 11: ...y Silverdale 7 The diagram below shows the stove with all internal parts taken out To install the internals simply follow the numbered sequence 1 9 and to remove simply reverse this process GB12A Issu...

Страница 12: ...re that the operating instructions for the stove are left with the consumer Ensure to advise the customer on the correct use of the appliance and warn them to use only the recommended fuel for the sto...

Страница 13: ...need to be operated correctly to control the combustion rate of the stove Secondary Air Intake Primary Air Intake T The main door handle on these appliances will get hot but are removable To remove th...

Страница 14: ...e through left to right so the slider can control the total amount of air required for suitable combustion The secondary air intake brings in air above the grate this air is drawn down the inside of t...

Страница 15: ...e coating of soot and tar in the chimney is volatile creating a high risk of chimney fires A growing tree contains a high percentage of water the wood needs to be dried out seasoned before it is suita...

Страница 16: ...ndling onto the newspaper ensure their is sufficient air gaps between the kindling a criss cross or pyramid style pattern is ideal to accomplish this Kindling Newspaper Stage 2 Ignite the paper undern...

Страница 17: ...own the Secondary Air Intake as required You can now control the burn rate of the stove using the secondary air intake You are looking for a controlled flame not smouldering in the embers or licking a...

Страница 18: ...ster in the devolved administrations The Amalia Oppdal and Silverdale 5 7 has been recommended as suitable for use in smoke control areas when burning wood logs Further information on the requirements...

Страница 19: ...lead to over firing Over firing is caused when too much heat is generated within the fire chamber this will lead to warping buckling and general damage to the stove and its internal components Over fi...

Страница 20: ...is possible that the higher flue gas temperature from a closed appliance may loosen deposits that were previously firmly adhered with the consequent risk of flue blockage It is therefore recommended...

Страница 21: ...being drawn up the chimney to waste Green or wet wood is being burnt The chimney has excessive draw this is unusual Seek installer advice with regard to installing a Flue Draught Stabiliser The stove...

Страница 22: ...Address _________________________________________________________________ Telephone Inc area code ____________________________________________________ HETAS Registration Number _______________________...

Страница 23: ...10 Side Firebricks x2 11 Bottom Side Firebricks x2 12 Grate 13 Bottom Front Firebrick 14 Ash Pan 15 Fixings M5 16 M5 Washers 17 Latch 18 Slider 19 Handle Knob 20 Handle 21 Door 22 Knob 23 Hinge Pin 24...

Страница 24: ...2 10 Side Firebricks x2 11 Bottom Side Firebricks x2 12 Grate 13 Bottom Front Firebrick 14 Ash Pan 15 Fixings M5 16 M5 Washers 17 Latch 18 Slider 19 Handle Knob 20 Handle 21 Door 22 Knob 23 Hinge Pin...

Страница 25: ...S WAY BATTLEFIELD ENT PARK SHREWSBURY SY1 3AB ph 44 0 1743 461444 MANUFACTURER RRF Rhein Ruhr Feuerst tten Pr fstelle GmbH NOTIFIED BODY RRF 1625 Firmensitz Im Lipperfeld 34 b D 46047 Oberhausen The f...

Страница 26: ...S WAY BATTLEFIELD ENT PARK SHREWSBURY SY1 3AB ph 44 0 1743 461444 MANUFACTURER RRF Rhein Ruhr Feuerst tten Pr fstelle GmbH NOTIFIED BODY RRF 1625 Firmensitz Im Lipperfeld 34 b D 46047 Oberhausen The f...

Страница 27: ...DRESS POSTCODE 3RD YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POST...

Страница 28: ...or components will become the property of Broseley Fires Should you wish to claim under the warranty please contact the supplier dealer from whom you purchased the appliance Do not claim directly to B...