background image

 
 

Hestia EVA5/A7 Issue 1 30/06/2014 

 

 
 

         

 

 

Installation & Operating 

Instructions

 

 
 
 
 

        

 

 
 
 
 

Covering Models: 

 

 

Hestia 5 & Hestia 7 

(EV-A5-CD1 & EV-A7-CD1) 

Wood Burning Stoves  

 

 

  

Tested to EN 13240 

 

 

These appliances must be installed and commissioned by a HETAS registered engineer

 

Содержание Hestia 5 EV-A5-CD1

Страница 1: ...0 06 2014 1 Installation Operating Instructions Covering Models Hestia 5 Hestia 7 EV A5 CD1 EV A7 CD1 Wood Burning Stoves Tested to EN 13240 These appliances must be installed and commissioned by a HE...

Страница 2: ...plained 14 Air wash System 14 Ash Pan 14 Recommended Fuels 15 Lighting the Stove Kindling Stage 16 Burning Wood 17 Smoke Exempt Requirements 18 Lighting sequence in smoke controlled areas 19 Warning N...

Страница 3: ...n must comply with current Building Regulations Local Authority By laws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regula...

Страница 4: ...uilding regulations require that whenever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwelling an audible carbon monoxide alarm must be fitted in the same room as...

Страница 5: ...for intermittent use European standards need to be complied with when installing this appliance Hestia 5 EV A5 CD1 Hestia 7 EV A7 CD1 Nominal Heat Output Wood to Room kW 5 7 Efficiency 77 8 76 6 Weig...

Страница 6: ...Hestia EVA5 A7 Issue 1 30 06 2014 6 Dimensions Hestia 5 Hestia 7 ALL DIMENSIONS ARE IN MILIMETRES...

Страница 7: ...sion in front of the stove to carpets or wooden floors must be at least 300mm As it is possible that on opening the door of the stove for fuel to fall out a fender must be fitted if the hearth is flus...

Страница 8: ...to the top of the chimney e g anti down draft cowl to eliminate wind induced down draft The outlet from the chimney should be above the roof of the building in accordance with the provisions of Buildi...

Страница 9: ...le glazing etc Under UK building regulations any appliance over 5kW MUST have a fixed permanent air vent see building regulations approved document J for further information There must not be an extra...

Страница 10: ...sue 1 30 06 2014 10 Assembly Hestia 5 EV A5 CD1 The diagram below shows the stove with all internals taken out To install the internals simply follow the numbered sequence 1 9 and to remove simply rev...

Страница 11: ...1 30 06 2014 11 Assembly Hestia 7 EV A7 CD1 The diagram below shows the stove with all internal parts taken out To install the internals simply follow the numbered sequence 1 9 and to remove simply r...

Страница 12: ...tion and commissioning ensure that the operating instructions for the stove are left with the consumer Ensure to advise the customer on the correct use of the appliance and warn them to use only the r...

Страница 13: ...ir controls these controls need to be operated correctly to control the combustion rate of the stove Secondary Air Intake Primary Air Intake T The main door handle on these appliances will get hot but...

Страница 14: ...ar air intake is adjustable through left to right so the slider can control the total amount of air required for suitable combustion The secondary air intake brings in air above the grate this air is...

Страница 15: ...will cause heavy deposits of soot and tar to accumulate on the glass and throughout the stove and flue The coating of soot and tar in the chimney is volatile creating a high risk of chimney fires A g...

Страница 16: ...a generous amount of dry kindling onto the newspaper and ensure their is sufficient air gaps between the kindling a criss cross or pyramid style pattern is ideal to accomplish this Kindling Newspaper...

Страница 17: ...e down the Secondary Air Intake as required You can now control the burn rate of the stove using the secondary air intake You are looking for a controlled flame not smouldering in the embers or lickin...

Страница 18: ...olved administrations The EV A5 CD1 and EV A7 CD1 have both been recommended as suitable for use in smoke control areas when burning wood logs when fitted with a mechanical stop preventing full closur...

Страница 19: ...with the doors open will lead to over firing Over firing is caused when too much heat is generated within the fire chamber this will lead to warping buckling and general damage to the stove and its i...

Страница 20: ...n open fire previously it is possible that the higher flue gas temperature from a closed appliance may loosen deposits that were previously firmly adhered with the consequent risk of flue blockage It...

Страница 21: ...the chimney to prevent heat being drawn up the chimney to waste Green or wet wood is being burnt The chimney has excessive draw this is unusual Seek installer advice with regard to installing a Flue D...

Страница 22: ...__________________________ Address _________________________________________________________________ Telephone Inc area code ____________________________________________________ HETAS Registration Num...

Страница 23: ...8 Steel Box 9 Rear Firebrick 10 Side Firebricks x2 11 Bottom Side Firebricks x2 12 Grate 13 Bottom Front Firebrick 14 Ash Pan 15 Fixings M5 16 M5 Washers 17 Latch 18 Slider 19 Handle Knob 20 Handle 2...

Страница 24: ...Steel Box 9 Rear Firebricks x2 10 Side Firebricks x2 11 Bottom Side Firebricks x2 12 Grate 13 Bottom Front Firebrick 14 Ash Pan 15 Fixings M5 16 M5 Washers 17 Latch 18 Slider 19 Handle Knob 20 Handle...

Страница 25: ...mbH NOTIFIED BODY RRF 1625 Firmensitz Im Lipperfeld 34 b D 46047 Oberhausen The following harmonised standards and Technical specifications have been met and comply with good engineering practice and...

Страница 26: ...mbH NOTIFIED BODY RRF 1625 Firmensitz Im Lipperfeld 34 b D 46047 Oberhausen The following harmonised standards and Technical specifications have been met and comply with good engineering practice and...

Страница 27: ...No COMPANY NAME COMPANY ADDRESS POSTCODE 3RD YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPAN...

Страница 28: ...ioned units Replaced parts or components will become the property of Broseley Fires Should you wish to claim under the warranty please contact the supplier dealer from whom you purchased the appliance...

Отзывы: