SmartLINK Module EIB3000MRF

for Mains Powered Multi-Sensor / Smoke / Heat / CO 
Alarms - EIB3000 Series

Instruction Manual

Read and retain carefully for as long as the product is being used. It contains vital 
information on the operation and installation of your Alarm. The leaflet should be 
regarded as part of the product.
If you are just installing the unit, the leaflet 

MUST

 be given to the householder. The 

leaflet is to be given to any subsequent user.

Содержание SmartLINK EIB3000 Series

Страница 1: ...d retain carefully for as long as the product is being used It contains vital information on the operation and installation of your Alarm The leaflet should be regarded as part of the product If you a...

Страница 2: ...2...

Страница 3: ...13 4 Additional Features 18 5 Troubleshooting and Indicator summary tables 21 6 Testing the System 28 7 Interconnected CO Alarms and Smoke Alarms 31 8 SmartLINK Troubleshooting 33 9 Technical Specific...

Страница 4: ...4 1 Introduction...

Страница 5: ...ions to existing sites Data Extraction to collect important information on the Alarm status including activations tests CO levels faults etc Monitoring buddy system where the strongest RF signal paths...

Страница 6: ...6 2 Installation and House Coding...

Страница 7: ...rm Push the lower half of the Alarm away from the screwdriver in the direction of the arrow on the cover see Figure 1 below CAUTION The existing hard wired interconnection may need to be disconnected...

Страница 8: ...of its length is inserted Fig 2a Then hold the module housing Fig 2b and plug it into the Alarm being careful to align the pins and keeping them perpendicular to the base as the module is inserted Fi...

Страница 9: ...The flashing will repeat every 5 seconds thereafter Repeat this procedure for all Alarms in the system Check to ensure all RF devices have been successfully House Coded This can be done by counting th...

Страница 10: ...ease of installation and RF communication that up to 12 RF devices can be installed in any one RF coded system Please contact us for further advise if additional RF devices are required Figure 4 blue...

Страница 11: ...House Code has been completed Factory Reset Sometimes in order to resolve an RF communication issue it may be necessary to reset factory reset and House Code the system again To do so press and hold t...

Страница 12: ...12 Pin Alignment Figure 5b Pin Alignment Figure 5c Figure 5a...

Страница 13: ...13 3 System Installations...

Страница 14: ...rconnected and RF interconnected Alarms and devices Hybrid systems can be very flexible and allow extended fire and or CO protection with minimum installation disruption When a hybrid system installed...

Страница 15: ...hat the alarm type is indicated correctly to the RF network during activation Hardwired Carbon Monoxide Alarm EIB3018 Hardwired Carbon Monoxide Alarm Fire CO Alarm Interface Figure 6 EIB3018 EIB413 Ha...

Страница 16: ...d system can consist of a mixture of Multi Smoke Heat and or CO Alarm types Fire CO Alarm Interface EIB413 System Alarm Controller EIB450 RF Multi Sensor Alarm EIB3024 RF Carbon Monoxide Alarm EIB3016...

Страница 17: ...should be fitted to a Multi Smoke and Heat only section one per section and that EIB3028 should also be the section s link to the RF network of the hybrid system Fire CO Alarm Interface EIB413 EIB3016...

Страница 18: ...18 4 Additional Features...

Страница 19: ...sufficient time so that all Alarms are now house coded correctly this can be confirmed by counting the number of flashes on each Alarm You can then exit House Code mode manually or let it exit automat...

Страница 20: ...Code Button until the green LED lights solid and then release Alternatively it will automatically exit monitoring mode after 30 minutes Monitoring is now enabled in the network If a paired Alarm then...

Страница 21: ...21 5 Troubleshooting and Indicator summary tables...

Страница 22: ...ue LED Red LED Green LED Sound Alarm Head Removal Mode Standby Normal Operation LED on solid LED flashing Button Test x 1 x 1 x 1 x 1 x 1 x 1 followed by flash every 10 Sec followed by flash 1 minute...

Страница 23: ...In house code House code exit Press and release on flashing blue Factory reset Press and release on multi colour flashing Remote learn entry In monitoring paired Press and release on solid green Press...

Страница 24: ...What it means What to do Fault Conditions rapidly after button release Rapid Beeping Incompatible house code Factory reset the module and re try Communication failure between module and Alarm head Re...

Страница 25: ...kly button test 5 1 3 Monthly button test Press and hold the test button The Alarm will sound and the blue LED will light for 3 5 seconds to indicate RF transmission of the test message 5 1 4 Sensing...

Страница 26: ...the module hold the House Code Button until the blue LED flashes and then release The blue LED will then flash rapidly for a few seconds to indicate a successful reset followed by a single blue flash...

Страница 27: ...a red flash Monitoring is now disabled in the network 5 3 Fault Conditions 5 3 1 Incompatible House coding This can occur if a previously house coded module has been swapped from one Alarm head to an...

Страница 28: ...28 6 Testing the System...

Страница 29: ...enovations to the house To test an individual Alarm press and hold the test button until the horn sounds and the green or red light flashes This will ensure that the sensor electronics and sounder are...

Страница 30: ...00MRF modules if fitted should be removed to prevent the batteries becoming fully depleted This is sometimes done with holiday homes which are only occupied in the summer End of Life EOL Check Once th...

Страница 31: ...31 7 Interconnected CO Alarms and Smoke Alarms...

Страница 32: ...it has its red light flashing rapidly this it the source of the alarm If it is a Carbon Monoxide Alarm ventilate the residence and follow the instructions in the Carbon Monoxide Alarm manual If it is...

Страница 33: ...33 8 SmartLINK Troubleshooting...

Страница 34: ...ocate the Alarms e g move them away from metal surfaces or wiring After making these changes to the RF signal path the SmartLINK signals may still not be reaching all the Alarms in your system even th...

Страница 35: ...35 9 Technical Specifications...

Страница 36: ...ight Temperature Range 0 to 40 C Humidity Range 15 to 95 Relative Humidity Interconnect Up to 12 SmartLINK modules Optional Accessories EIB407 Manual Call Point EIB428 Relay Module Ei414 Fire CO Alarm...

Страница 37: ...37 10 Guarantee...

Страница 38: ...ed This guarantee excludes incidental and consequential damage If this RF SmartLINK Module should become defective within the guarantee period it must be returned to Brooks with proof of purchase care...

Страница 39: ...39 11 Limitations of Radio Communications...

Страница 40: ...d i Receivers may be blocked by radio signals occurring on or near their operating frequencies regardless of the House Coding ii Alarms with SmartLINK modules should be tested regularly at least weekl...

Страница 41: ...41 Conforms to AS NZS 4268 2017...

Страница 42: ...42...

Страница 43: ...43...

Страница 44: ...Box 101 Woodville SA 5011 729A Port Road Woodville SA 5011 Ph 08 8347 0000 QLD P O Box 511 Archerfield QLD 4108 2 49 Boyland Ave Coopers Plains QLD 4108 Ph 07 3373 8222 WA P O Box 2114 Midland DC W A...

Отзывы: