Maintenance and Repair
MagnaTran 7.1 User’s Manual
Robot Removal/Replacement
MN-003-1600-00
Brooks Automation
9-26
Revision 2.2
Top Mount
1.
Attach the lifting eye-bolts to the robot’s mounting collar.
2.
Attach a hoist to the lifting bolts.
Ergonomic Hazard - The MagnaTran 7 Drive weighs 29.5 kg (65 lbs.) 3
axis or 21 kg (46.5 lbs.) 2 axis. Failure to take the proper precautions
before moving it could result in personal injury.
3.
Unscrew the twelve captive M6 mounting bolts from the chamber, do
not remove the mounting bolts from the robot’s mounting collar, and
raise the robot body.
To install the MagnaTran 7 robot, reverse the preceding steps. Be sure that the align-
ment pins are properly aligned before seating and bolting the robot’s mounting collar.
Tighten all mounting bolts until the lock washers are fully seated, then tighten the
bolts an additional
1
/
4
turn.
HEAVY LIFTING