MagnaTran 7.1 User’s Manual
Command Reference
MN-003-1600-00
Set Sync Phase
Brooks Automation
Revision 2.2
8-149
Set Sync Phase
Purpose
Sets the Sync Phase for the T1, T2 and Z motors.
CAUTION
This command is NOT used in the normal operation of the robot. Call
Brooks Automation Technical Support for instructions on the correct
use of this command.
Format
SET SYNC PHASE [ALL] t1value t2value zvalue
or
SET SYNC PHASE [T1 t1value |T2 t2value|Z zvalue]
Arguments
t1value:
The calculated average T1 value
t2value:
The calculated average T2 value
zvalue:
The calculated average Z value
Description
This command is used to enter the average calculated value from the FIND PHASE
command.
DANGER
This command is NOT used in the normal operation of the robot. See
Motor Electrical Phase Calibration on page 9-69
and
Board Replacement on page 9-58
for instructions on this command.