![Brooks Automation MagnaTran 7.1 Скачать руководство пользователя страница 383](http://html1.mh-extra.com/html/brooks-automation/magnatran-7-1/magnatran-7-1_user-manual_2818788383.webp)
MagnaTran 7.1 User’s Manual
Command Reference
MN-003-1600-00
Request Workspace
Brooks Automation
Revision 2.2
8-115
Request Workspace
Purpose
This command is used to request the current setting of the specified work space
parameter(s) for either the specified work space name or all defined work spaces.
Format
RQ WSPACE name [ALL|(STATE|INTLCK|ARM|STN|RMIN|RMAX|TMIN|
TMAX|ZMIN|ZMAX)]
Response
name state intlck arm stn rmin rmax tmin tmax zmin zmax
Arguments
name:
Specifies the work space name
state:
ACTIVE or INACTIVE
intlck:
Name of a mapped SVLV_SEN or SBIT_SVLV_SEN type input
arm:
A, B, or BOTH
stn:
1 - 16
rmin:
Robot retract value to robot maximum extension value in microns
rmax:
Robot retract value to robot maximum extension value in microns
tmin:
0 - 360000 (microns)
tmax:
0 - 360000 (microns)
zmin:
0 to robot maximum Z vertical height in microns
zmax:
0 to robot maximum Z vertical height in microns
Description
Indicates the current setting of the specified work space parameter(s) for the
requested name or for all defined work spaces.
See Also: