MagnaTran 7.1 User’s Manual
Operation
MN-003-1600-00
Shut-down
Brooks Automation
Revision 2.2
6-91
Shut-down
The robot requires no special shut-down procedures. Once use of the robot is com-
plete, power can be removed.
•
Ensure that the robot has completed all transfer operations and that there are
no wafers left on the end effectors.
•
If the host controller is to be shut off, the robot should be shut-down first.
•
SET commands only load parameter values into RAM. These values will be
reset to default values if power is removed. If permanent storage of values is
desired, STORE values using appropriate commands before shut-down.