Brocade FastIron X Series Chassis Hardware Installation Guide
109
53-1001723-02
Hitless management support
5
Once you enter this command, the system will prompt you as follows.
Are you sure? (enter ’y’ or ’n’): y
Running Config data has been changed. Do you want to continue
the switch-over without saving the running config? (enter ’y’ or ’n’): n
Please save the running config and try switch-over again
Syntax: switch-over-active role
Rebooting the active and standby management modules
You can use the boot system or reload commands to reboot the management modules,
maintaining the currently configured active management module (the management module to
which the set-active-mgmt command applies).
For example, to reboot the active and standby management modules from the primary IronWare
image in the management module’s flash memory, enter the following command at the Privileged
EXEC level.
FastIron# boot system flash primary
Syntax: boot system bootp | [flash primary | flash secondary] | slot | tftp <
ip-address
>
<
filename
>
The flash primary keyword specifies the primary IronWare image in the management module’s
flash memory, while the flash secondary keyword specifies the secondary IronWare image in the
flash memory.
The tftp keyword directs the switch to boot from an IronWare image on a TFTP server located at
<ip-address> with the specified <filename>.
NOTE
To reboot the device from a TFTP server through a
fiber
connection, use the CLI command boot
system tftp <ip-address> <filename> fiber-port.
For example, to reboot the active and standby management modules, enter the following command
at the Privileged EXEC level.
FastIron# reload
Syntax: reload
Hitless management support
This section discusses the following Hitless management features.
•
Layer 2 Hitless Switchover – A CLI-driven switchover of the active and standby management
modules without interruption to switched traffic.
•
Layer 2 Hitless Operating System (OS) Upgrade – An operating system upgrade without
interruption to switched traffic.
NOTE
Layer 2 Hitless OS Upgrade is
not
supported when upgrading the device from software release
05.1.00 to 07.0.01b.
Содержание FastIron SX 1600
Страница 8: ...viii Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 ...
Страница 96: ...68 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Verifying proper operation 2 ...
Страница 114: ...102 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Removing MAC address entries 4 ...
Страница 200: ...188 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Detailed procedure A ...
Страница 204: ...192 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Russia B ...