The following table describes the CP blade LED patterns and the recommended actions for those patterns.
TABLE 7
CP blade LED descriptions
LED purpose
Color
Status
Recommended action
Power
Steady green
CP blade is on.
No action required.
No light (LED is off)
CP blade is not on.
Ensure that the blade is firmly
seated and has power.
Status
No light (LED is off)
CP blade is either healthy or
does not have power.
Verify that the power LED is on.
Steady amber
CP blade is faulty or the switch is
still booting.
Ensure that the blade is firmly
seated and the switch has
completed booting. If LED
remains amber, consult the
Brocade DCX supplier.
Slow-flashing amber (on 2
seconds, then off 2 seconds)
CP blade is not seated correctly
or is faulty.
Pull the blade out and reseat it. If
the LED continues to flash,
replace the blade.
Fast-flashing amber (on 1/2
second, then off 1/2 second)
Environmental range exceeded.
Check for out-of-bounds
environmental condition and
correct it.
Ethernet Link Status
No light (LED is off)
Either an Ethernet link is not
detected, or it does not have
incoming power.
Ensure that the blade has power,
the Ethernet cable is firmly
seated, and the connected device
is functioning.
Flickering green/amber
Ethernet link is healthy and traffic
is flowing through port.
No action required.
Ethernet Link Speed
No light (LED is off)
Ethernet link speed is 10 Mb/s
or CP blade does not have
incoming power.
Ensure that the CP has power.
NOTE:
To force a persistent
Ethernet link speed, enter the
ifModeSet
command.
Steady green
Ethernet link speed is
100/1000 Mb/s.
No action required.
USB Status
Lamp on
USB stick enabled.
No action required.
Lamp off
USB stick not present or
disabled.
No action required.
Active CP
Steady blue
Active CP blade.
No action required.
No light (LED is off)
Standby CP blade.
No action required.
Determining the status of a core switch blade (CR8)
1. Check the LED indicators on the core switch (CR) blade. The LED patterns may temporarily change during POST and other
diagnostic tests. For information about how to interpret the LED patterns, see the next table.
Determining the status of a core switch blade (CR8)
Brocade DCX Backbone Hardware Installation Guide
74
53-1000685-24
Содержание DCX Backbone
Страница 8: ...Brocade DCX Backbone Hardware Installation Guide 8 53 1000685 24...
Страница 12: ...Brocade DCX Backbone Hardware Installation Guide 12 53 1000685 24...
Страница 14: ...Brocade DCX Backbone Hardware Installation Guide 14 53 1000685 24...
Страница 24: ...Brocade DCX Backbone Hardware Installation Guide 24 53 1000685 24...
Страница 28: ...Brocade DCX Backbone Hardware Installation Guide 28 53 1000685 24...
Страница 46: ...Brocade DCX Backbone Hardware Installation Guide 46 53 1000685 24...
Страница 50: ...Brocade DCX Backbone Hardware Installation Guide 50 53 1000685 24...
Страница 82: ...Brocade DCX Backbone Hardware Installation Guide 82 53 1000685 24...
Страница 138: ...Brocade DCX Backbone Hardware Installation Guide 138 53 1000685 24...
Страница 142: ...Brocade DCX Backbone Hardware Installation Guide 142 53 1000685 24...
Страница 148: ...Brocade DCX Backbone Hardware Installation Guide 148 53 1000685 24...
Страница 154: ...FIGURE 53 FS8 18 encryption blades Brocade DCX Backbone Hardware Installation Guide 154 53 1000685 24...