5. Open the terminal emulator application and configure as follows:
For most MS Windows systems:
Bits per second: 9600Databits: 8Parity: NoneStop bits: 1Flow control: None
NOTE
Flow control is not supported on the serial consoles when attached to remote terminal servers and must be disabled
on the customer-side remote terminal server and the host-side clients.
In a UNIX environment, type the following string at the prompt:
tip /dev/ttyb -9600
If ttyb is already in use, use
ttya
instead and enter the following string at the prompt:
tip /dev/ttya -9600
When the terminal emulator application stops reporting information, press
Enter
. You receive the following login prompt:
CP0 Console Login:
Logging in to the serial console port
To log in to the Brocade DCX through the serial connection, follow these steps.
1. Log in to the Brocade DCX as
admin
. The default password is
password
. You are prompted to change the default passwords at
initial login. Make sure to write down the new passwords and keep this information in a secure location.
Fabric OS (swDir)
swDir login: admin
Password:
Please change your passwords now.
Use Control-C to exit or press 'Enter' key to proceed.
Password was not changed. Will prompt again at next login
until password is changed.
swDir:admin>
2. (Optional) Modify passwords. To skip modifying the password, press Ctrl-C. For more information on passwords, refer to the
Brocade Fabric OS Administration Guide
.
NOTE
Passwords can be 8 to 40 characters long. They must begin with an alphabetic character. They can include numeric
characters, the dot (.), and the underscore (_) only. Passwords are case-sensitive, and they are not displayed when you
enter them on the command line.
Configuring the IP addresses
The Brocade DCX requires three IP addresses, which are configured using the
ipAddrSet
command. IP addresses are required for both
CP blades (CP0 and CP1) and for the chassis management IP (shown as SWITCH under the
ipAddrShow
command) in the Brocade
DCX.
Logging in to the serial console port
Brocade DCX Backbone Hardware Installation Guide
54
53-1000685-24
Содержание DCX Backbone
Страница 8: ...Brocade DCX Backbone Hardware Installation Guide 8 53 1000685 24...
Страница 12: ...Brocade DCX Backbone Hardware Installation Guide 12 53 1000685 24...
Страница 14: ...Brocade DCX Backbone Hardware Installation Guide 14 53 1000685 24...
Страница 24: ...Brocade DCX Backbone Hardware Installation Guide 24 53 1000685 24...
Страница 28: ...Brocade DCX Backbone Hardware Installation Guide 28 53 1000685 24...
Страница 46: ...Brocade DCX Backbone Hardware Installation Guide 46 53 1000685 24...
Страница 50: ...Brocade DCX Backbone Hardware Installation Guide 50 53 1000685 24...
Страница 82: ...Brocade DCX Backbone Hardware Installation Guide 82 53 1000685 24...
Страница 138: ...Brocade DCX Backbone Hardware Installation Guide 138 53 1000685 24...
Страница 142: ...Brocade DCX Backbone Hardware Installation Guide 142 53 1000685 24...
Страница 148: ...Brocade DCX Backbone Hardware Installation Guide 148 53 1000685 24...
Страница 154: ...FIGURE 53 FS8 18 encryption blades Brocade DCX Backbone Hardware Installation Guide 154 53 1000685 24...