NOTE
Refer to "Cabling Best Practices" (available at
) for cable management
guidelines.
For the procedure to install the ICL cables, refer to
Inter-chassis link (ICL) cable removal and
on page 108
Verifying correct operation and backing up the configuration
To verify correct operation and back up the Brocade DCX 8510-8 configuration, follow these steps. For
information about LED patterns, refer to
Determining the status of a port or application blade
on page
54.
Complete the following steps to back up the configuration for the Brocade DCX 8510-8.
1. Check the LEDs to verify that all components are functional.
2. If necessary, log in to the switch by Telnet, using the
admin
account.
3. Verify the correct operation of the Brocade DCX 8510-8 by entering the
switchShow
command from
the workstation. This command provides information about switch and port status.
4. Verify the correct operation of the Brocade DCX 8510-8 in the fabric by entering the
fabricShow
command from the workstation. This command provides general information about the fabric.
5. To back up the configuration, run the following two steps:
a)
Enter the
configupload -vf
command. This command uploads the Brocade DCX 8510-8
virtual fabric data.
b)
Enter the
configupload
command. This command uploads the Brocade DCX 8510-8
configuration.
6. You can run the following commands to see additional configuration information that you can copy to
a file to save:
•
configShow
•
ipaddrShow
•
licenseShow
•
switchShow
Alternatively, you can save the configuration file to a Brocade USB device by using the
usbstorage
command.
NOTE
Passwords are not saved in the configuration file, and are not uploaded during a configuration
upload.
NOTE
It is recommended that the configuration be backed up on a regular basis to ensure that a complete
configuration is available for downloading to a replacement Brocade DCX 8510-8.
Verifying correct operation and backing up the configuration
Brocade DCX 8510-8 Backbone Hardware Reference Manual
47
53-1002180-08
Содержание DCX 8510-8
Страница 1: ...53 1002180 08 19 September 2014 Brocade DCX 8510 8 Backbone Hardware Reference Manual ...
Страница 12: ...What s new in this document 12 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 22: ...Network manageability 22 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 34: ...Installing ICL cables 34 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 148: ...Port Numbering Template 148 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 166: ...Brocade DCX 8510 Technical Specifications 166 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 172: ...Danger Notices 172 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...