The Brocade DCX 8510-8 can be accessed through a remote connection using the command line
via Telnet or any of the management tools, such as Web Tools or Brocade Network Advisor.
4. To complete any additional Brocade DCX 8510-8 configuration procedures through a Telnet
session, log in to the Brocade DCX 8510-8 by Telnet, using the
admin
login. The default password
is
password
.
Customizing a switch name
The switch name of the Brocade DCX 8510-8 can be up to 30 characters long using Fabric OS
release 7.0.0 or later; can include letters, numbers, hyphens, and underscore characters; and must
begin with a letter.
NOTE
Changing the name causes a domain address format RSCN to be issued.
1. Enter
switchName
followed by the new name in double quotes.
swDir:admin> switchName "swModularSwitch5"
Committing configuration...
Done.
swModularSwitch5:admin>
2. Record the new name for reference.
Customizing a chassis name
The chassis name of the Brocade DCX 8510-8 can be up to 15 characters long; can include letters,
numbers, hyphens, and underscore characters; and must begin with a letter.
1. Enter
chassisName
followed by the new name in double quotes.
switch:admin> chassisname
"DCX8510_chassis"
Committing configuration...
Done.
2. Enter
chassisName
by itself to show the name.
switch:admin> chassisname
DCX8510_chassis
3. Record the new name for reference.
Setting the domain ID
Each switch in the fabric must have a unique domain ID. The domain ID can be manually set through
the
configure
command or can be automatically set. The default domain ID for the Brocade DCX
8510-8 is 1. Use the
fabricShow
command to view the already assigned domain IDs.
1. Enter
switchDisable
to disable the Brocade DCX 8510-8.
2. Enter
configure
.
Customizing a switch name
40
Brocade DCX 8510-8 Backbone Hardware Reference Manual
53-1002180-08
Содержание DCX 8510-8
Страница 1: ...53 1002180 08 19 September 2014 Brocade DCX 8510 8 Backbone Hardware Reference Manual ...
Страница 12: ...What s new in this document 12 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 22: ...Network manageability 22 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 34: ...Installing ICL cables 34 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 148: ...Port Numbering Template 148 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 166: ...Brocade DCX 8510 Technical Specifications 166 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 172: ...Danger Notices 172 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...