Environmental status and maintenance commands
TABLE 17
Command
Information displayed
sensorShow
Temperature readings for the port blades
Temperature readings for the CP blades
Status and RPM of all operational fans
Status of all operational power supplies
tempShow
Temperature readings for the port blades
Temperature readings for the CP blades
psShow
Status of all operational power supplies
fanShow
Status and RPM of all operational fans
chassisShow
Serial number, time awake, and additional information about each component
slotShow
Slot occupancy
errShowerrDump
System error log. Refer to the
Fabric OS Message Reference
for more information on the
messages in this log.
Interpreting POST and boot results
The Brocade DCX 8510-8 performs Power-On Self-Test (POST) by default each time the chassis is
powered on, rebooted, or reset. The Brocade DCX 8510-8 can be rebooted using the
reboot
(to
reboot each CP individually) or
fastBoot
commands. The
fastBoot
command reboots the switches
without running POST. If the active CP blade is rebooted, it fails over to the standby CP blade.
POST
The Brocade DCX 8510-8 automatically performs POST each time it is powered on or reset.
To verify that POST has completed without error, do the following:
• Verify that all LEDs return to a normal state after POST completes.
If one or more LEDs do not return to a normal state, and this is not due to the Brocade DCX 8510-8
being set to beacon, refer to the relevant LED table to identify and correct the problem. For port
blades, and CP and core switch blades, the
slotShow
command can be used to check the status of
the slots. For information about turning beaconing on or off, refer to the
Fabric OS Administrator's
Guide
.
• Verify that the switch prompt displays when POST completes.
If it does not display, POST was not successfully completed. Contact the Brocade DCX 8510-8
supplier for support.
• Review the system error log using the
errShow
or
errDump
commands.
Interpreting POST and boot results
132
Brocade DCX 8510-8 Backbone Hardware Reference Manual
53-1002180-08
Содержание DCX 8510-8
Страница 1: ...53 1002180 08 19 September 2014 Brocade DCX 8510 8 Backbone Hardware Reference Manual ...
Страница 12: ...What s new in this document 12 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 22: ...Network manageability 22 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 34: ...Installing ICL cables 34 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 148: ...Port Numbering Template 148 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 166: ...Brocade DCX 8510 Technical Specifications 166 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 172: ...Danger Notices 172 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...