Broan VB0310 Скачать руководство пользователя страница 16

4. C

ONTROLS

 

(

CONT

D

)

 4.5 

M

AIN

 W

ALL

 C

ONTROL

 D

ESCRIPTION

16

The included wall control is 40405 (intented for EVO5 500 HRV and EVO5 700 HRV HEPA Venmar units only) or 40410 (intented for 
HRV 5.1 and HRV 7.1 HEPA Broan units only). The wall control is in OFF mode when power is applied for the first time. 
After a power failure, the wall control returns to its original operation mode. 

VC0131

LCD screen. 
Backlight: If the backlight is 
not illuminated, the first key 
pressed (no matter which key) 
shall turn on the backlight. The 
backlight remains illuminated for 
10 seconds after the last key is 
pressed.

MODE key

TURBO function key

ON/OFF key. 
When wall control is OFF, the 
unit is on stand-by mode, so 
it will only respond to override 
wall control (if present). Only 
the house icon appears on LCD 
screen. When wall control is 
ON, the house icon is still there, 
and the label mode in which the 
unit operates appears at the 
bottom of LCD screen. See 
operation modes for more details.

ECO mode key

4.6.1 O

PERATION

 M

ODES

 4.6 

M

AIN

 W

ALL

 C

ONTROL

 U

SE

When the wall control is ON, press the MODE key to choose the operation mode of the ventilation unit. 
Operating Mode label will then appear on LCD screen (AUTO, ECO, CONT and RECIRC).

AUTO M

ODE

The ventilation unit exchanges air intermittently on a one-hour cycle as follows: exchanges air during 20 minutes on low speed 
and then recirculation on high speed for 40 minutes (or OFF for 40 minutes, see section 4.6.3). Repeat cycle after the 40-minute 
period. 

NOTE:  The outdoor temperature value displayed during AUTO recirculation or AUTO off cycle period comes from the reading 
 

while the unit is performing air exchange (first part of AUTO mode cycle). Also, keep in mind that outdoor temperature 

 

reading is taken from the unit fresh air from outside port; due to the lenght of the insulated duct, the result of the reading is 

 

slightly different from the real outside temperature.

F

IRST

 

PART

 

OF

 

THE

 

CYCLE

L

AST

 

PART

 

OF

 

THE

 

CYCLE

20 minutes of air 

exchange in low 

speed

40 minutes de 

recirculation en 

haute vitesse

40 minutes OFF 

in AUTO mode

OR

20 minutes of air 

exchange in low 

speed

F

IRST

 

PART

 

OF

 

THE

 

CYCLE

L

AST

 

PART

 

OF

 

THE

 

CYCLE

Содержание VB0310

Страница 1: ...HEPA HRV 5 1 These products earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA They meet ENERGY STAR requirements only when used in Ca...

Страница 2: ...ugged into a mating 3 prong grounding receptacle grounded in accordance with the national electrical code and local codes and ordinances Do not remove the ground prong Do not use an extension cord 8 D...

Страница 3: ...RTS 11 3 7 INSTALLING DUAL EXTERIOR HOOD 11 12 3 7 1 ASSEMBLING DUAL EXTERIOR HOOD 11 3 7 2 LOCATING DUAL EXTERIOR HOOD 11 3 7 3 CONNECTING TANDEM TRANSITION TO DUAL EXTERIOR HOOD 12 3 8 CONNECTING TH...

Страница 4: ...evel Homes with more than one level require at least one exhaust register at the highest level See figure at right 1 2 CENTRAL DRAW POINT CONNECTION TO A FORCED AIR SYSTEM VH0089 Stale air coming from...

Страница 5: ...NSITION VD0118A 8 222 mm 9 248 mm The joist opening needed to install theTandem tansition included in ISKV1000 and ISKB1000 installation kits must be 9 248 mm minimum Also the maximumheightoftheTandem...

Страница 6: ...stallation date on the HEPA filter frame for future reference see illustration at right TO P DES SU S FR O N T AV A N T Ins tal dat e Da te d in sta l _ _ _ _ _ _ _ _ 212 93 F R O N T A V A N T In st...

Страница 7: ...minimum Do not ventilate crawl spaces or cold rooms Do not attempt to recover the exhaust air from a dryer or a range hood This would cause clogging of the filters and recovery module If the house ha...

Страница 8: ...level to ensure the greatest possible air circulation Keep in mind that the fresh air diffuser must be located as far as possible from the stale air diffuser If desired you can install another diffuse...

Страница 9: ...orresponding port then do the same for the exhaust air to building duct and port See illustration at right NOTE Use an insulated duct not included if the duct will have to go through a space where it...

Страница 10: ...will need two exterior hoods instead of one In this case do not use the Tandem transition go to point 3 6 2 and refer to the optional single hood enclosed instructions For each duct pull back the ins...

Страница 11: ...around the joint Compressed insulation loses its insulation properties and causes water dripping due to condensation on the exterior surface of the duct CAUTION 3 7 INSTALLING DUAL EXTERIOR HOOD Exte...

Страница 12: ...de duct will be located on top CAUTION VD0085 XMAS TREE PIN Join the end of the Tandem transition to the rear of the exterior backplate Secure with 2 Xmas tree pins and seal properly with duct tape Th...

Страница 13: ...of the LED will show on which defrost cycle the unit is set NOTE No command will be taken until the unit is fully booted 4 2 DEFROST CYCLES Five seconds after the booting sequence is done the LED 2 wi...

Страница 14: ...tic operation of the unit and or the wall control Never install more than one main wall control per ventilation unit Keep control low voltage wiring at least 1 foot 305 mm away from motors lighting ba...

Страница 15: ...artment interface Plug the unit Usetheterminalconnectorincludedintheinstallationkittoperformtheelectricalconnection for main and optional wall controls Check if all wires are correctly inserted in the...

Страница 16: ...key 4 6 1 OPERATION MODES 4 6 MAIN WALL CONTROL USE When the wall control is ON press the MODE key to choose the operation mode of the ventilation unit Operating Mode label will then appear on LCD scr...

Страница 17: ...t was in TURBO mode for this particular case the unit will get back to the mode chosen before TURBO mode When the wall control is ON no matter the operation mode pressing on TURBO key will turn the un...

Страница 18: ...AYED TEMPERATURE UNIT NOTE Prior to perform this setting the wall control must be ON Press and hold on ECO key during 4 seconds NOTE To get back to C for temperature display repeat the complete proced...

Страница 19: ...appear on screen while 25 13 will flash factory set value OR according to the displayed temperature unit chosen To enter a lower value press on ECO key to enter a higher value press the TURBO key OR 4...

Страница 20: ...ances When the wrench icon appears on wall control screen perform the required maintenance according to the unit model MAINTENANCE TABLE FOR EVO5 500 HRV AND HRV 5 1 UNITS APPEARANCE MAINTENANCE TYPE...

Страница 21: ...wall of the unit with a damp cloth then wipe with a dry one Remove dust on core using a vacuum cleaner with a soft brush attachment Wash both core filters under hot water with mild soap Rinse thoroug...

Страница 22: ...water and mild soap dishwashing liquid Rinse carefully drain off water and reinstall with its filters For EVO5 700 HRV HEPA and HRV 7 1 HEPA units only The heat recovery core must be reinstalled BEFO...

Страница 23: ...cold at the air supply grille on cold season Check if the exterior hood is not blocked specifically the top grille Set the unit in AUTO or ECO mode See Control section 4 6 1 Operation modes on pages 1...

Страница 24: ...enuine replacement parts only The manufacturer genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintai...