background image

MODEL

S110FLUE

TYPICAL INSTALLATION

The unit can be
installed in a
suspended ceiling
using wire as shown.

The unit will operate
most quietly when
located where the
shortest possible
duct run and
minimum number of
elbows will be
needed.

Plan to supply the
unit with proper line
voltage and appropriate power cable.

Follow these basic steps when installing this unit:

• Nail housing to joists.
• Attach ductwork.
• Connect power cable.
• Install blower assembly.
• Fasten grille to housing.

INSTALLER:  LEAVE THIS MANUAL WITH THE HOMEOWNER.

HOMEOWNER:  USE AND CARE INSTRUCTIONS ON PAGE 3.

SOLITAIRE ULTRA-SILENT

®

FLUORESCENT FAN / LIGHT / NIGHT LIGHT

READ  AND  SAVE  THESE  INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service

panel and lock service panel to prevent power from being
switched on accidentally.

3. Installation work and electrical wiring must be done by a

qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.

4. Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.

5. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

WARNING

6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.

8. Never place a switch where it can be reached from a tub or

shower.

9. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust

hazardous or explosive materials and vapors.

2. This product is designed for ceiling installation only. This

product is designed for installation in ceilings up to a 12/12
pitch. Ductwork must point up. DO NOT MOUNT THIS PROD-
UCT IN A WALL.

3. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power
unit.

4. Please read specification label on product for further informa-

tion and requirements.

POWER

CABLE

SUSPENDED CEILING

MATERIAL

4" ROUND 

DUCT

HOUSING

HOUSING

MOUNTING

BRACKET

CEILING

JOIST

POWER

CABLE

GRILLE

FINISHED CEILING

4" ROUND

DAMPER/DUCT

CONNECTOR

This unit can be installed anywhere between joists using
mounting brackets provided.

Broan at

::

bathroomsource

.

com

is a division of

kitchen

::

accessories

U      N      L      I      M      I      T      E      D

::

bathroomsource

.

com

                   

Call 1-800-667-8721 anywhere in the US and Canada -

www.bathroomsource.com

Содержание SOLITAIRE ULTRA-SILENT S110FLUE

Страница 1: ...ufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers AS...

Страница 2: ...uring guides on corners of housing to check if unit will be flush with finished ceiling Pound nails tight For wide joist centers A 8 x 3 8 self tapping screw can be used to join extended brackets toge...

Страница 3: ...ong screws provided DONOTOVERTIGHTEN Dam age to grille may result 3 Install bulbs See Use and Care instructions for bulb specifications 4 Snap light lens into place 5 Turn on power and check fan and l...

Страница 4: ...e above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To...

Страница 5: ...r donde pueda ser alcanzado desde un ba o o ducha 9 Esta unidad debe ser conectada a tierra PRECAUCION 1 Solamente para uso de ventilaci n general No se use para extraer materiales o vapores peligroso...

Страница 6: ...da en las esquinas de la caja para comprobar si la unidad est a nivel con el techo acabado Clave los clavos completamente Para centros de viga anchos se puede usar un tornillo autorroscante 8 x 3 8 pa...

Страница 7: ...on una tela suave NO USE TELAS ABRASIVAS ESPONJILLAS DE LANA DE ACERO O POLVOS ABRASIVOS Para limpiar el conjunto ventilador Quite la rejilla desconecte las luces y el motor saque el tornillo y retire...

Страница 8: ...aplicarse a usted Esta garant a le proporciona derechos legales espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as...

Отзывы: