MODEL  QTX110SL   

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OB-

SERVE THE FOLLOWING:

1.  Use this unit only in the manner intended 

by the manufacturer. If you have questions, 

contact the manufacturer at the address or 

telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch 

power off at service panel and lock the ser-

vice disconnecting means to prevent power 

from being switched on accidentally. When 

the service disconnecting means cannot be 

locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be 

done by a qualified person(s) in accordance 

with all applicable codes and standards, 

including fire-rated construction codes and 

standards.

4.  Sufficient air is needed for proper combustion 

and exhausting of gases through the flue 

(chimney) of fuel burning equipment to pre

-

vent backdrafting. Follow the heating equip-

ment manufacturer’s guideline and safety 

standards such as those published by the 

National Fire Protection Association (NFPA), 

and the American Society for Heating, Re-

frigeration and Air Conditioning Engineers 

(ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do 

not damage electrical wiring and other hidden 

utilities.

6.  Ducted fans must always be vented to the 

outdoors.

7.  Acceptable for use over a tub or shower when 

connected to a GFCI (Ground Fault Circuit 

Interrupter) - protected branch circuit.

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use 

to exhaust hazardous or explosive materials 

and vapors.

2.  This product is designed for installation in 

flat ceilings only. DO NOT MOUNT THIS 

PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy 

and/or unbalanced impellers, keep drywall 

spray, construction dust, etc. off power unit.

4.  Please read specification label on product for 

further information and requirements.

HUMIDITY SENSING

FAN / LIGHT / NIGHT LIGHT

READ AND SAVE THESE INSTRUCTIONS

CLEANING & 

MAINTENANCE

Installer: Leave this manual 

with the homeowner.

For quiet and efficient operation, long life, 

and attractive appearance - lower or remove 

grille and vacuum interior of unit with the 

dusting brush attachment.

The  motor  is  permanently  lubricated  and 

never needs oiling. If the motor bearings are 

making excessive or unusual noises, replace 

the motor with the exact service motor. The 

impeller should also be replaced.

SENSOR CLEANING

The humidity sensor is mounted in the grille. 

The sensor will operate most reliably when 

cleaned occasionally as follows:

1. Disconnect power at service entrance.

2. Remove the grille. Use a dry dustcloth, 

clean toothbrush, or lightly vacuum to 

clean sensor and grille. DO NOT USE 

ABRASIVE  CLOTH,  STEEL  WOOL 

PADS, OR SCOURING POWDERS.

3. DO NOT USE cleaning sprays, solvents, 

or water on or near the sensor!

OPERATION

The humidity control, fan, light, and night 

light can be operated separately. Use a 3- or 

4-function wall control. Do not use a dimmer 

switch  to  operate  the  humidity  control  or 

light. See “Connect Wiring” for details.

SENSOR OPERATION

The  humidity-sensing

 

fan  uses  a  sophis-

ticated  humidity  sensor  that  responds  to: 

(a)  rapid  to  moderate  (user-adjustable) 

increases in humidity or (b) humidity above 

a  user-adjustable  set-point  (50%-100% 

relative  humidity).  The  humidity  sensor 

may  occasionally  turn  the  fan  ON  when 

environmental  conditions  change.  If  the 

fan  continuously  responds  to  changing 

environmental  conditions,  “SENSITIVITY” 

adjustment may be required.

MANUAL ON WITH TIMED OFF

The humidity sensing fan has an additional 

operation feature. For odor or vapor con-

trol,  the  fan  can  be  energized  by  cycling 

the power switch. Once the fan has been 

energized in this manner, it will remain on 

for the user-adjustable “TIMER” period (5 

to  60  minutes). This  period  is  factory-set 

for 20 minutes.

To manually energize the fan:

1. If  fan  power  switch  is  already  ON, 

proceed to Step 2; otherwise, turn power 

switch ON for more than 1 second.

2. Turn fan power switch OFF for less than 

1 second.

3. Turn fan power switch back ON and fan 

will turn ON.

SENSITIVITY ADJUSTMENT

The “SENSITIVITY” has been factory set 

for  most  shower  applications.  However, 

if the fan is in a tub area or is being used 

for dampness control, the “SENSITIVITY” 

may need to be increased toward maximum 

(“MAX.”).  If  the  control  is  responding  too 

often to changing environmental conditions, 

movement toward less (“MIN.”) “SENSITIV

-

ITY” may be required.

To adjust the “SENSITIVITY”:

1. Disconnect power at service entrance.

2. Through the grille, locate the screwdriver 

slot marked “SENSITIVITY”.

3. Using  a  small,  flat-blade  screwdriver, 

carefully  rotate  the  “SENSITIVITY” 

adjustment toward “MAX.” or “MIN.”

4. Turn on power and check operation by 

turning on the shower or other humidity 

source until the fan turns on.

5. Repeat above steps if necessary.

TIMER  ADJUSTMENT

The humidity sensing fan has a “TIMER” 

that can be adjusted from 5 to 60 minutes 

(factory-set at 20 minutes). This “TIMER” 

controls the length of time that the fan re-

mains ON (a) after the sensor has stopped 

sensing a rise in humidity and the humidity 

level is below the user-adjustable set-point 

or (b) after being energized by cycling the 

power switch.

To adjust the “TIMER”:

1. Disconnect power at service entrance.

2. Through the grille, locate the screwdriver 

slot marked “TIMER”.

3. Using  a  small,  flat-blade  screwdriver, 

carefully rotate the “TIMER” adjustment 

to  desired  setting  (from  5  to  60 

minutes).

4. Check operation by cycling the power 

switch  as  instructed  under  “MANUAL 

ON  WITH TIMED  OFF”  or  by  turning 

on a humidity source until the fan turns 

on.

5. Turn humidity source off and time the 

unit.

6. Repeat above steps if necessary.

To register this product visit:

www.broan.com

Содержание QTX110SL

Страница 1: ...R SCOURING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor OPERATION The humidity control fan light and night light can be operated separately Use a 3 or 4 function wall c...

Страница 2: ...est holes NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each mounting flange and the I joist OR ROOF CAP 6 in ROUND ELBOW 6 in ROUND DUCT WALL CAP Purchas...

Страница 3: ...framing 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL approved connector to secure house wiring to wiring plate Connect wires as shown in wiring diagrams...

Страница 4: ...FLUORESCENT LAMP STARTERSAND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance...

Страница 5: ...NI POLVOS ABRASIVOS 3 NO USE sprays limpiadores solventes ni agua en o cerca del sensor OPERATION El control de humedad el ventilador la l mpara y la l mpara de noche pueden funcionar sepa radamente U...

Страница 6: ...medad No la ponga cerca de una ventana La unidad puede responder a los niveles de humedad del exterior La unidad se debe instalar en el cielo raso para detectar adecuadamente la humedad Ubique la unid...

Страница 7: ...para que funcione autom ticamente 1b Instale la cubierta en cualquier parte entre las armaduras viguetas o viguetas I por medio de barras de suspensi n Se proporcionan barras de suspensi n deslizantes...

Страница 8: ...BOS DE LAS L MPARAS FLUORES CENTES Esta garant a no cubre a mantenimiento y servicio normales ni b ning n producto o piezas que se hayan sometido a uso inadecuado negligencia accidente mantenimiento o...

Отзывы: