background image

Page 1

MODELS QTRE080H • QTRE100H

WARNING  

  

TO  REDUCE THE  RISK  OF  FIRE,  ELECTRIC  SHOCK,  OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 
or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel  and  lock  the  service  disconnecting  means  to  prevent 
power from being switched on accidentally. When the service 
disconnecting  means  cannot  be  locked,  securely  fasten  a 
prominent warning device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by qualified 

personnel in accordance with all applicable codes and standards, 
including fire-rated construction codes and standards.

4.  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to 
prevent backdrafting. Follow the heating equipment manufacturer’s 
guideline and safety standards such as those published by the 
National Fire Protection Association (NFPA), and the American 
Society for Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities.

5.  When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Acceptable  for  use  over  a  tub  or  shower  when  connected  to 

a  GFCI  (Ground  Fault  Circuit  Interrupter)  -  protected  branch 
circuit.

8.  This unit must be grounded.
9.  When  applicable  local  regulations  comprise  more  restrictive 

installation and/or certification requirements, the aforementioned 
requirements prevail on those of this document and the installer 
agrees to conform to these at his own expenses.

10. When performing installation, servicing or cleaning this unit, it 

is recommended to wear safety glasses and gloves.

CAUTION  

!

1.  For general ventilating use only. Do not use to exhaust hazardous 

or explosive materials and vapors.

2.  This product is designed for installation in flat ceilings only. DO 

NOT MOUNT THIS PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 
unit.

4.  Please read specification label on product for further information 

and requirements.

MODELS QTRE080H 
AND QTRE100H
HUMIDITY SENSING FANS

READ AND SAVE THESE INSTRUCTIONS

CLEANING & MAINTENANCE

Installer: Leave this manual with the homeowner.

For quiet and efficient operation, long life, and attractive appearance 
- lower or remove grille and vacuum interior of unit with the dusting 
brush attachment.
The motor is permanently lubricated and never needs oiling. If the 
motor bearings are making excessive or unusual noises, replace 
the motor with the exact service motor. The impeller should also 
be replaced.

SENSOR CLEANING

The humidity sensor is mounted in the control housing. The sensor 
will operate most reliably when cleaned occasionally as follows:

1.  Disconnect power at service entrance.
2.  Remove  the  grille.  Use  a  dry  dustcloth,  clean  toothbrush, 

or  lightly  vacuum  to  clean  sensor  and  grille.  DO  NOT  USE 
ABRASIVE  CLOTH,  STEEL WOOL  PADS,  OR  SCOURING 
POWDERS.

3.  DO NOT USE cleaning sprays, solvents, or water on or near 

the sensor!

OPERATION

The humidity control and fan can be operated separately. Use a 
1- or 2-function wall control. Do not use a dimmer switch to operate 
the humidity control. See “Connect Wiring” for details.

SENSOR OPERATION

The  humidity-sensing

 

fan  uses  a  sophisticated  humidity  sensor 

that responds to: (a) rapid to moderate increases in humidity or 
(b) humidity above a set-point. The humidity sensor may occasionally 
turn the fan ON when environmental conditions change.

MANUAL ON WITH TIMED OFF

The humidity sensing fan has an additional operation feature. For 
odor  or  vapor  control,  the  fan  can  be  energized  by  cycling  the 
power switch. Once the fan has been energized in this manner, it 
will remain on for 20 minutes.
To manually energize the fan:

1.  If fan power switch is already ON, proceed to Step 2; otherwise, 

turn power switch ON for more than 1 second.

2.  Turn fan power switch OFF for less than 1 second.
3.  Turn fan power switch back ON and fan will turn ON.

BB0004