background image

Page

MODEL   QTR140

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power  from  being  switched  on  accidentally.  When  the  ser-

vice disconnecting means cannot be locked, securely fasten 

a  prominent  warning  device,  such  as  a  tag,  to  the  service 

panel.

3.  Installation  work  and  electrical  wiring  must  be  done  by  a 

qualified  person(s)  in  accordance  with  all  applicable  codes 

and  standards,  including  fire-rated  construction  codes  and 

standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of  gases  through  the  flue  (chimney)  of  fuel  burning  equip

-

ment to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the local code authori

-

ties.

5.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Acceptable for use over a tub or shower when connected to 

a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit (ceiling installation only).

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard

-

ous or explosive materials and vapors.

2.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

3.  Please read specification label on product for further informa

-

tion and requirements.

MODEL QTR140
VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

CLEANING & MAINTENANCE

WARRANTY

BROAN-NUTONE THREE YEAR LIMITED WARRANTY

Broan-NuTone warrants to the original consumer purchaser of its products 

that such products will be free from defects in materials or workmanship 

for a period of three years from the date of original purchase. THERE ARE 

NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT 

NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR 

FITNESS FOR A PARTICULAR PURPOSE.

During this three-year period, Broan-NuTone will, at its option, repair or 

replace, without charge, any product or part which is found to be defective 

under normal use and service.

THIS  WARRANTY  DOES  NOT  EXTEND  TO  FLUORESCENT  LAMP 

STARTERS  AND  TUBES.  This  warranty  does  not  cover  (a)  normal 

maintenance and service or (b) any products or parts which have been 

subject to misuse, negligence, accident, improper maintenance or repair 

(other than by Broan-NuTone), faulty installation or installation contrary to 

recommended installation instructions.

The duration of an implied warranty is limited to the three-year period as 

specified for the express warranty. Some states do not allow limitation 

on how long an implied warranty lasts, so the above limitation may not 

apply to you.

BROAN-NUTONE’S  OBLIGATION  TO  REPAIR  OR  REPLACE,  AT 

BROAN-NUTONE’S  OPTION,  SHALL  BE  THE  PURCHASER’S  SOLE 

AND  EXCLUSIVE  REMEDY  UNDER  THIS  WARRANTY.  BROAN-NU-

TONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL 

OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH 

PRODUCT USE OR PERFORMANCE. Some states do not allow the ex

-

clusion or limitation of incidental or consequential damages, so the above 

limitation may not apply to you.

This warranty gives you specific legal rights, and you may also have other 

rights, which vary from state to state. This warranty supersedes all prior 

warranties.

To qualify for warranty service, you must (a) notify Broan-NuTone at the 

address or telephone number stated below, (b) give the model number and 

part identification and (c) describe the nature of any defect in the product or 

part. At the time of requesting warranty service, you must present evidence 

of the original purchase date.

Broan-NuTone LLC    Hartford, Wisconsin 

www.broan.com    800-558-1711

Installer: Leave this manual with the homeowner.

For quiet and efficient operation, long life, and attractive appear

-

ance - lower or remove grille and vacuum interior of unit with the 

dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the 

motor bearings are making excessive or unusual noises, replace 

the motor with the exact service motor. The impeller should also 

be replaced.

OPERATION

Use an on/off switch or speed control to operate this ventilator. 

See “Connect Wiring” for details.

Содержание QTR140

Страница 1: ... ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this three year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warr...

Страница 2: ...F CAP 6 in or 4 in ROUND ELBOW 6 in or 4 in ROUND DUCT WALL CAP Purchase separately The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed Use a roof cap or wall cap that has a built in damper to reduce backdrafts Plan to supply the unit with proper line voltage and appropriate power cable ...

Страница 3: ...rk Connect 6 inch or 4 inch round duc twork to damper duct connector Run ductwork to a roof cap or wall cap Tape all ductwork connections to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs contact the bottom of the joist The housing mounts with four 4 screws ...

Страница 4: ...2 req d 14 99111293 Spacer 2 supplied 15 475 Duct Reducer 6 to 4 16 99420665 Thumbscrew 8 18 x 375 INSTALL GRILLE 7 Attach grille to housing Squeeze grille springs and insert them into slots on each side of hous ing 8 Push grille against ceil ing 6 Finish ceiling Install ceiling material Cut out around housing SERVICE NOTE To remove Blower Assem bly Unplug motor 7 Remove thumbscrew 16 from motor p...

Страница 5: ... tos estarán libres de defectos en cuanto a material y mano de obra durante un período de tres años a partir de la fecha de la compra original NO EXISTEN OTRAS GARANTÍAS EXPRESAS NI IMPLÍCITAS INCLUIDAS PERO SIN LIMITARSE A GARANTÍAS IMPLÍCITAS DE COMERCIAL IZACIÓN O IDONEIDAD PARA UN PROPÓSITO PARTICULAR Durante este período de tres años Broan NuTone a su criterio reparará o reemplazará sin cargo...

Страница 6: ...O REDON DO DE 6 o 4 PULG CONDUCTO REDONDO DE 6 o 4 PULG TAPA DE PARED Se compran por separado El ventilador funcionará con más eficiencia y menos ruido si se ubica en un sitio donde requiera el tramo de conducto más corto posible y un mínimo número de codos Instale una tapa de techo o de pared que tenga un regulador de tiro incorporado a fin de reducir los contratiros Alimente la unidad con el vol...

Страница 7: ...le reductor de conducto de 6 á 4 pulg sobre conector de conducto 4 Instale el conducto redondo de 6 o 4 pulga das Conecte el conduc to redondo de 6 o 4 pulgadas al conec tor del regulador conducto Extienda el conducto hacia una tapa de techo o tapa de pared Encinte todas las conexiones de los conductos para fijarlas y hacerlas herméticas al aire 2 Monte la cubierta en la vigueta Sostenga la cubi e...

Страница 8: ...665 Tornillo de mariposa n o 8 18 x 0 375 INSTALE LA REJILLA 7 Acople la rejilla a la cubierta Apriete los resortes de la rejilla e insér telos en las ranuras que se encuentran a cada lado de la cubierta 8 Empuje la rejilla contra el cielo raso 6 Termine el cielo raso Instale el material del cielo raso Recorte alrededor de la cubierta NOTA DE SERVICIO Para desmontar el conjunto del ventilador Dese...

Отзывы: