background image

Page 1

MODELS   QTR080L • QTR110L

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the service 

disconnecting  means  cannot  be  locked,  securely  fasten  a 

prominent warning device, such as a tag, to the service panel.

3.  Installation  work  and  electrical  wiring  must  be  done  by  a 

qualified  person(s)  in  accordance  with  all  applicable  codes 

and  standards,  including  fire-rated  construction  codes  and 

standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of  gases  through the  flue  (chimney)  of  fuel  burning  equip-

ment to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the local code authori-

ties.

5.  When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Acceptable for use over a tub or shower when connected to 

a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit.

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2.  This product is designed for installation in ceilings up to a 7/12 

pitch. Duct connector must point up. DO NOT MOUNT THIS 

PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power 

unit.

4.  Please read specification label on product for further informa-

tion and requirements.

QTR SERIES
FAN / LIGHT / NIGHT LIGHTS

READ AND SAVE THESE INSTRUCTIONS

CLEANING & MAINTENANCE

WARRANTY

Installer: Leave this manual with the homeowner.

For quiet and efficient operation, long life, and attractive appear-

ance - lower or remove grille and vacuum interior of unit with the 

dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the 

motor bearings are making excessive or unusual noises, replace 

the blower assembly (includes motor and impeller).

OPERATION

The fan, light, and night light can be operated separately. Use a 

3-function wall control. See “Connect Wiring” for details.

To register this product visit:

www.broan.com

BROAN-NUTONE THREE YEAR LIMITED WARRANTY

Broan-NuTone warrants to the original consumer purchaser of its products that 

such products will be free from defects in materials or workmanship for a period 

of  three  years  from  the  date  of  original  purchase. THERE ARE  NO  OTHER 

WARRANTIES,  EXPRESS  OR  IMPLIED,  INCLUDING,  BUT  NOT  LIMITED 

TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 

PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or replace, 

without charge, any product or part which is found to be defective under normal 

use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, 

TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, 

ROOF  CAPS, WALL  CAPS AND  OTHER ACCESSORIES  FOR  DUCTING. 

This warranty does not cover (a) normal maintenance and service or (b) any 

products  or  parts  which  have  been  subject  to  misuse,  negligence,  accident, 

improper maintenance or repair (other than by Broan-NuTone), faulty installation 

or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the three-year period as specified 

for the express warranty. Some states do not allow limitation on how long an 

implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S  OBLIGATION TO  REPAIR  OR  REPLACE, AT  BROAN-

NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE 

REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE 

FOR  INCIDENTAL,  CONSEQUENTIAL  OR  SPECIAL  DAMAGES ARISING 

OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. 

Some states do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, 

which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or 

telephone number below, (b) give the model number and part identification and (c) 

describe the nature of any defect in the product or part. At the time of requesting 

warranty service, you must present evidence of the original purchase date.
Broan-NuTone  LLC,  926  W.  State  Street,  Hartford,  Wisconsin  53027 

www.broan.com    800-558-1711

Содержание QTR080L

Страница 1: ...the motor bearings are making excessive or unusual noises replace the blower assembly includes motor and impeller OPERATION The fan light and night light can be operated separately Use a 3 function w...

Страница 2: ...45o NOT FOR USE IN A COOKING AREA The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed Use a roof cap or wal...

Страница 3: ...ions to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs con...

Страница 4: ...otor Remove thumbscrew 11 from motor plate flange Find the single TAB on the motor plate located next to the receptacle Push up near motor plate tab while pushing out on side of housing Or insert a st...

Страница 5: ...i n Conexi n el ctrica Para registrar este producto visite www broan com LIMPIEZA Y MANTENIMIENTO Para lograr un funcionamiento silencioso y eficiente como tambi n larga vida y una apariencia atractiv...

Страница 6: ...COCINA El ventilador funcionar con m s eficiencia y menos ruido si se ubica en un sitio donde requiera el tramo de conducto m s corto posible y un m nimo n mero de codos Instale una tapa de techo o d...

Страница 7: ...xiones de los conductos para fijarlas y hacerlas herm ticas al aire 3 Acople el conectador del regulador de tiro conducto Conecte a presi n el conectador del regu lador de tiro conduc to en la cubiert...

Страница 8: ...servicio se debe especificar el n mero de la pieza no el n mero de la clave 8 Empuje la rejilla contra el cielo raso 10 Instale las bombillas Compre una bombilla incan descente m x 100 W Compre una bo...

Отзывы: