background image

MODELS  QP230BC • QP230BL • QP230SS • QP230WW

QP236BC • QP236BL • QP236SS • QP236WW

QP242BC • QP242BL • QP242SS • QP242WW

Page 5

12 

DUCTED INSTALLATION ONLY:

Remove 3¼” x 10 vertical, 3¼” x 10” horizontal, or 7-inch 

round 

knockout plate(s)

 as appropriate for your ducting 

method.

3¼” X 10”

HORIZONTAL

KNOCKOUT

PLATE

3¼” X 10”

VERTICAL

KNOCKOUT

PLATE

7” ROUND

KNOCKOUT

PLATE (also 

remove 3¼” x 10” 

vertical plate)

7” ROUND 

DUCT 

PLATE

INSTALL THE HOOD

15 

Run 

House Power Cable

 between service panel and hood 

location. Attach power cable to hood using appropriate clamp.

16 

Hang hood from (4) mounting screws driven part-way into 

cabinet locations (shown in illustrations under “PREPARE 

HOOD LOCATION”). Mounting screws are included in parts 

bag. Slide hood back towards wall until mounting screw 

heads are engaged in narrow end of keyhole slots in top of 

hood. Tighten screws securely. Add 5th mounting screw in 

center hole in hood and tighten securely.

17 

DUCTED INSTALLATION ONLY:

Connect ductwork to hood and use duct tape to make joints 

secure and air-tight.

 

Make sure the damper / duct connector 

enters the ductwork and that the damper opens and closes 

freely.

HOUSE

POWER CABLE

WARNING

 

 

To reduce the risk of electrical shock, switch power off  

 

 

at service panel. Lock or tag service panel to prevent    

 

 

power from being switched on accidentally.

ELECTRICAL 

WIRING BOX 

COVER

14 

Remove 

Electrical Wiring Box Cover

 from inside 

of hood and appropriate 

Electrical Power Cable 

Knockout

 from top or back of hood.

ELECTRICAL 

POWER

CABLE

KNOCKOUT

13 

DUCTED INSTALLATION ONLY:

Attach 

3¼” x 10” Damper/Duct Connector

 (if using 3¼” 

x 10” duct) or 

7” Round Duct Plate

 (if using 7-inch round 

duct) over the knockout opening.

Notes:

To accomodate off-center ductwork, the 3¼” x 10” 

damper/duct connector can be installed up to ½” on either 

side of the hood center and the 7” round duct plate can 

be installed up to ½” on either side of the hood center.
Install the 3¼” x 10” Damper/Duct Connector with the 

Damper Flap Pivot

 nearest the 

Top/Back Edge of 

Hood

.

TOP/BACK

EDGE OF

HOOD

DAMPER

FLAP

PIVOT

3¼” X 10”

DAMPER / 

DUCT 

CONNECTOR

Отзывы: