background image

Overture

TM

 WALL CONTROL

INCLUDED

Wall Control Part No. 1103434
User Manual
Quick Start Guide
Note: Wall plate not included – Use Broan Part No.
S97012925 (or equivalent)

1103414A

For Warranty Statement, Service Parts, Technical 
Support, or to Register your product, please visit our 
website or call: In the United States - Broan-NuTone.com
800-558-1711. In Canada - Broan.ca or NuTone.ca
877-896-1119

CONTROL SPECIFICATIONS

• cULus 

Listed

•  120 VAC 60 Hz Line Power
• Maximum load ½ HP Motor, 15A Resistive,

15A Inductive, 3A Incandescent, 0.6A Electronic Ballast

• When used in combination with fan/light fixtures

that are switched together, the device is rated for the 
following lamps: 360W Incandescent, 72W LED, or
72W CFL

• For Control of Electronic Ballast, CFLs, LED and LED

lamps or the equivalent

• Typical Wire Sizes: 12AWG (MAX) or 14AWG solid

copper wire rated for at least 90°C

•  Operating temperature: 32-95°F (0-35°C)
•  Purpose of Control: Operating Control
•  Rated impulse voltage: 2500 V

SAFETY

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.  Before installing the wall control, switch power off at 

the service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel. CAUTION: 
Risk of Electric Shock - More than one disconnect
switch may be required to de-energize the equipment 
before servicing.

2. All electrical work must be done in accordance with

local codes, ordinances, or National Electrical Code,
as applicable, including fire-rated construction codes 
and standards. FOR SAFETY, THIS PRODUCT MUST
BE GROUNDED. If you are unfamiliar with methods
of installing electrical wiring, secure the services of a 
qualified electrician.

3.  Use copper wire only.
4.  WARNING: This device shall not be used in combination

with a wall switch controlling a receptacle.

5. Install only in a UL Listed junction box sized

2.0 x 3.0 x 3.0 in. (50.8 x 76.2 x 76.2 mm) or larger, with 
a minimum volume of 18.0 in

3

 (295 CM

3

) for 14AWG 

wiring and 20.0 in

3

 (328 CM

3

) for 12AWG wiring.

6.  This control requires a neutral wire for operation.
7. When cutting or drilling into wall or ceiling, do not

damage electrical wiring or other hidden utilities.

8. To prevent serious injury from electrical shock or

damage to electrical components - DO NOT WIRE
HOT!

9. The automatic operation feature is Type 1 action,

according to UL 60730-1.

10. The enclosure protection rating is IP30.
11. The product is Pollution Degree 2, which is intended 

to be used in a household environment or similar.

12. The devices are not intended for use in locations

where the temperature may be less than actual room 
conditions, such as unheated warehouses or garages.

13. Avoid water and wet locations. Keep the device

away from water, fire, excessive humidity, or hot
environments.

14. Do not use the device where wireless devices are

not allowed.

15. Do not attempt to disassemble, repair, or modify

the device. Don’t disassemble the product, or make
repairs yourself. You run the risk of electric shock
and voiding the limited warranty. If you need service, 
please contact us.

16. Note: When power is applied, the Wall Control 1103434 

may require approximately 30 seconds to boot up and 
be ready to function.

17. Please read and follow the above safety information 

when operating the device. We cannot guarantee that 
no accidents or damage will occur due to the improper 
use of the device. Please use this product with care
and operate at your own risk.

Warranty is void if miswired.

INSTALLATION

NOTE: This control requires a 120 VAC source (hot and 
neutral) in the switch box to operate the wall control.
1.  Turn off the power and lockout the service panel before 

wiring the control.

2. Location Notes:

a. For bathroom applications, the control should
be placed at a level to detect humidity. Placing the
control directly above a heater or near drafts is NOT
recommended.
b. For bathroom applications, the Wall Control should 
be placed in close proximity to the shower/tub/sink/
etc. (the main source of humidity/steam/VOC) and at 
sink height or higher for effective monitoring of your 
indoor air quality.
c. Place your Wall Control within the range of your
Wi-Fi router or access point (approximately 100 feet). 
d. Avoid physical obstructions and radio interference 
in the surrounding area.

3. Install the wall control in at least a 3” deep switch

box for #14 AWG wire or at least a 3 ½” deep switch
box for #12 AWG wire. The control can be installed in 
either a metal outlet box or a plastic outlet box.

4. Attach the incoming power line and ventilator power

line to switch box. It may be necessary to use two
side knockouts for some applications. Use proper
connectors. Provide 6” leads inside box and ventilation 
product.

5. Make electrical connections following the diagrams

provided below or in the Broan-NuTone Overture

TM

app. Use wire nuts. Make sure both the control and
the ventilator are properly grounded. Wire terminals
accept up to #12 AWG MAX solid wire.
a. Loosen screw terminals.
b. Strip wire 0.275” and insert the bare wire into the
screw terminal opening.
c. Tighten the terminal screw, making sure wire
remains under the clamp. Torque the terminal screws to
3.5 in-lbs (.4 N-m).
d. Note: Do not reuse wire formed into a “J” loop or
wrapped around screw threads. The screw terminal 
is designed for the straight insertion of stripped wire 
for proper mechanical and electrical connection.

6. Tuck wires in and fasten control to switch box using

attached screws. Verify wall control orientation before 
installation. Note “TOP” direction shown on the wall
control label.

7.  Attach switch plate (not included) using color-matched 

oval head screws.

8. Download the Broan-NuTone Overture

TM

 App for step by

step set-up instructions to connect your Wall Control 
to the Overture

TM

 system. Scan QR code to go to App 

Store.

Regulatory Information

The Overture

TM 

Wall Control 1103434 is certified to 

comply with applicable FCC and IC rules and regulations 
governing RF and EMI emissions. Refer to 1103434. 
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This 
device may not cause harmful interference, and (2) This 
device must accept any interference received, including
interference that may cause undesired operation.

FCC Notice

This equipment has been tested and found to comply with 
the limits for a Class B digital device, pursuant to Part 15 
of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in 
a residential installation. This equipment generates, 
uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions 
may cause harmful interference to radio communications. 
However, there is no guarantee that interference will 
not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television
reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following 
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and

receiver.

• Connect the equipment into an outlet on a circuit

different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV

technician to help.

Changes or modifications not expressly approved by the 
party responsible for compliance could void the user’s 
authority to operate the equipment.

ISED Compliance Statement

This device contains licence-exempt transmitter(s)/
receiver(s) that comply with Innovation, Science and 
Economic Development Canada’s licence-exempt RSS(s). 
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including

interference that may cause undesired operation of
the device.

The Bluetooth® word mark and logos are registered 
trademarks owned by Bluetooth SIG, Inc. and any use 
of such marks by Broan-NuTone LLC is under license. 
Other trademarks and trade names are those of their 
respective owners.

The Android robot is reproduced or modified from work 
created and shared by Google and used according to 
terms described in the Creative Commons 3.0 Attribution 
License.

Regulatory ID for 1103434 Overture

TM

 Wall Control

 

FCC ID: 2ADLL-1103434
IC: 2143B-1103434
M a d e   i n   C h i n a   t o   t h e   q u a l i t y   s t a n d a r d s   a n d

 

specifications of 
Broan-Nutone LLC Hartford, Wisconsin
www.broan-nutone.com 800-558-1711
Venmar Ventilation ULC Drummondville Quebec Canada 
www.broan.ca or www.nutone.ca 877-896-1119

For more information and user manuals scan QR code 
below.

The distance between user and device should be no less 

than 20cm.

la distance entre l'utilisation et l'appareil ne doit pas 

être inférieure à 20 cm.

M

BIAQWC100P

Overture Wall 

Control

L

N

IN

BIAQWC100P

Overture

TM

 Wall 

Control

L

N

IN

BL

K

GR

D

Switch Box

WH

T

Venlator

BLK

GRD

WHT

120 VAC

Power Supplied to Switch Box

S1

S2

Oponal :

M ode l De pendent

RED

BLK

WHT

Power Supplied to Venlator

M

BIAQWC100P

Overture Wall 

Control

L

N

IN

BIAQWC100P

Overture

TM

 Wall 

Control

L

N

IN

BLK

GRD

Switch Box

WHT

Venlator

BLK

GRD

WHT

120 VAC

LINE IN

S1

S2

Oponal :

M ode l De pendent

RED

WHT

1103414_A.indd 1

2020-11-24 10:33:28

Отзывы: