background image

INST
ALLA
TION MANUAL

OPERA

TION

5

Operation

Always turn your hood on before you begin cooking to establish an air flow in the kitchen.

Let the blower run for a few minutes to clear the air after you turn off the range. This will help 
keep the whole kitchen cleaner and fresher.

Operate the hood as follows:

BLOWER ACTIVATION/SPEED LEVEL CHANGE/FILTER INDICATOR RESET

When blowers are OFF, press on this push button to turn ON the blowers at the last saved speed. 
If there was no speed saved, the blowers will be set on LOW speed.
NOTE:  When LOW speed is activated from OFF, the blowers start on MEDIUM speed for a very 
   

short lapse of time, and then resume to LOW speed. 

To change the blower speed, press on this push button again until the desired speed is reached 
(from LOW to MEDIUM to HIGH speed to OFF). Each time a blower speed is activated, a rotating 
blower icon appears on left side of LCD screen, with dot(s) under it (the rotation speed shows the 
chosen speed: slow for LOW with one dot, faster for MEDIUM with 2 dots and fastest for HIGH 
with 3 dots). 
When blowers are on (no matter the speed level), press and hold this push button until the blower 
icon disappears from the LCD screen; this will turn off the blowers and save the blower speed 
chosen. 

Heat Sentry™

This hood is equipped with a protective device that activates the blowers when an abnormally high 
heat level is detected while the blowers are activated. During the Heat Sentry activation, this device 
takes control of the blowers and set them on MEDIUM speed while all dots under the blower icon 
blink. However, the lights can be still controlled. The blowers will remain on MEDIUM speed until 
the heat is back to normal, they then return to the speed previously selected.
NOTE:  When excessive heat is detected, Heat Sentry will shut off both blowers and lights while all 
   

dots under the blower icon will blink faster. Both blowers and lights will remain off until the 

   

ambient temperature cools down; the blowers will then start on MEDIUM speed (the lights 

   

can be controlled again). The blowers will remain on MEDIUM speed until the heat is back 

   

to normal, they then return to the speed previously selected.

NOTE:  At range hood start-up or after a power failure, a small icon (

1

) appears shortly 

   

(for ± 2 seconds) on LCD screen; this is normal.

FILTER CLEANING REMINDER

This icon appears on LCD screen 30 seconds after turning OFF the blowers when it is time to 
clean hood and filters (refer to Cleaning and Maintenance on page 7). This happens every time 
the blowers are turned OFF until the filter cleaning reminder has been reset. Once the cleaning is 
done, reset the filter cleaning reminder by pressing on blower activation push button for 3 seconds 
while the icon appears on LCD screen for 30 seconds.  

1

Содержание CRDN130BL

Страница 1: ...WWW BROAN CA Serial number 99045663 001H RANGE HOOD Series CRDN1 INSTALLATION USE AND CARE MANUAL...

Страница 2: ...g Installation 8 21 Recommended Tools and Accessories for Installation 8 Install Ductwork Ducted Installations Only 8 Contents 9 Prepare the Hood 10 13 Prepare the Hood Location 14 EZ1 Person Installa...

Страница 3: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines a...

Страница 4: ...d you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fi...

Страница 5: ...ipped with a protective device that activates the blowers when an abnormally high heat level is detected while the blowers are activated During the Heat Sentry activation this device takes control of...

Страница 6: ...vated temperatures of cooking offering bright lighting and lasting up to 25 times as long as a standard bulb and greater reliability than typical replacement LED bulbs MASTER ON OFF Press this push bu...

Страница 7: ...he center of the fan wheels should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water...

Страница 8: ...round duct is used Install Ductwork Ducted Installations Only SOFFIT 18 MIN 30 MAX ABOVE COOKING SURFACE CABINET 3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERT...

Страница 9: ...ce bord au mur arri re Utiliser ce gabarit pour marquer vos rep res ne pas tenter de d couper le trou pour le conduit travers le gabarit NOTE Les d coupes incluent le jeu n cessaire l installation el...

Страница 10: ...her use 3 Using the finger cup remove the grease filters from the hood by pushing down and tilting filters out 4 Using a 11 32 nutdriver or socket remove the lock nut retaining the flange of the right...

Страница 11: ...nstall an appropriate strain relief 1 2 diameter not included For knockout removed from top of hood the strain relief will be installed later ELECTRICAL POWER CABLE KNOCKOUT 5 Remove the parts bag tap...

Страница 12: ...PLATE SCREWS NON DUCTED INSTALLATION ONLY 7 Remove 3 screws retaining the recirculation cover plate to the hood Discard this plate with its screws Peel off and discard the membrane covering the recirc...

Страница 13: ...work the 7 round duct plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZON...

Страница 14: ...10 3 x 14 RECTANGULAR DUCTING 7 ROUND DUCTING OR Use this template for marking do not attempt to cut out the ducting hole through it NOTE These cutouts are clearance holes they do not need to be the e...

Страница 15: ...ws Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at B location...

Страница 16: ...Draw a line on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align side edge to marked line keeping the rear end edge leaning on the wall Use a pencil to...

Страница 17: ...hang the hood using its 2 recessed FRONT HOLES C and D While holding the hood go to step 6 5 Hang the hood on the brackets using the 2 recessed FRONT HOLES C and D While holding the hood tighten an ap...

Страница 18: ...ide in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using four 4 no 8 x 5 8 round head wood screws included in parts bag Insert two 2 screw...

Страница 19: ...ing screws are not included VERTICAL DUCT ACCESS HOLE 5 5 CENTER LINE ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 9 12 47 16 CABINET BOTTOM...

Страница 20: ...s wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely and maintain a hold on the hood until completing step 3 3 Secure the hood to the cab...

Страница 21: ...l wiring must be done by qualified personnel in accordance with all applicable codes and standards Before connecting wires switch power off at service panel and lock service disconnecting means to pre...

Страница 22: ...Override W W W W Transformer Heatshrink W R BK Ref 990729478A LED 2 1 LED 2 1 Note The control board is viewed with the connectors on the opposite side of the board W R BK O G Y 1 2 3 5 4 6 W R BK O G...

Страница 23: ...OVER PLATE STAINLESS STEEL INCLUDING SCREWS 1 2 S97020534 3 X 10 DAMPER ASSEMBLY INCLUDING SCREWS 1 1 1 3 S97020412 CAPACITOR INCLUDING TIE WRAP 2 2 2 4 S97020797 AUTOTRANSFORMER WITH SCREWS 1 1 1 5 S...

Страница 24: ...BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1...

Страница 25: ...ct or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part...

Страница 26: ...WWW BROAN CA Num ro de s rie 99045663 001H HOTTE DE CUISINI RE S rie CRDN1 MANUEL D INSTALLATION D UTILISATION ET D ENTRETIEN...

Страница 27: ...res recommand s pour l installation 8 Installation des conduits installations avec conduits seulement 8 Contenu 9 Pr paration de la hotte 10 13 Pr paration de l emplacement de la hotte 14 Syst me d in...

Страница 28: ...ons et aux standards de s curit des manufacturiers d quipement de chauffage tel qu ils sont publi s par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and...

Страница 29: ...aissez le fonctionnement B Le feu est petit et limit l endroit o il a d but C Les pompiers ont t avis s D Vous pouvez combattre le feu en ayant acc s une sortie de secours Tir es du Kitchen Fire Safet...

Страница 30: ...te est munie d un dispositif de protection qui active les ventilateurs lorsqu un niveau anormalement lev de chaleur est d tect lorsqu ils sont en fonction Lors de l activation du Heat Sentry ce dispos...

Страница 31: ...ronnement chaleur lev e Leur durabilit est jusqu 25 fois sup rieure celle d ampoules standards et ils sont plus robustes que les ampoules DEL typiques MARCHE ARR T PRINCIPAL Appuyer sur ce bouton pous...

Страница 32: ...r un chiffon propre imbib d une solution d eau chaude et de d tergent NETTOYAGE DE L ACIER INOXYDABLE faire Laver r guli rement les surfaces l aide d un chiffon propre imbib d eau chaude et de savon d...

Страница 33: ...des conduits de 7 po ronds sont utilis s Installation des conduits installations avec conduits seulement NOTE Une distance sup rieure 30 po demeure la discr tion de l installateur et de l utilisateur...

Страница 34: ...trav s de la plantilla NOTA To be translated in Spanish MARK WHERE INDICATED FOR THE APPROPRIATE SIZE DUCT OPENING MARQUER LES REP RES AUX ENDROITS INDIQU S SELON LE FORMAT DE CONDUIT UTILIS TITLE TO...

Страница 35: ...3 Enlever les filtres graisses en ins rant un doigt dans la prise concave de chaque filtre graisses puis en poussant vers l arri re de la hotte et en les basculant 1 2 3 4 5 6 7 4 l aide d un tourne...

Страница 36: ...s appropri de 1 2 po de diam tre non inclus Pour une ouverture pr amorc e retir e du dessus de la hotte le serre fils sera install plus tard OUVERTURE PR AMORC E DU C BLE D ALIMENTATION LECTRIQUE 5 Re...

Страница 37: ...rer les 3 vis retenant la plaque couvrant la grille de recirculation en gris dans l illustration ci dessous la hotte Se d faire de cette plaque et de ses vis Soulever et se d faire de la membrane reco...

Страница 38: ...ement jusqu 1 2 po de chaque c t pour s ajuster un conduit d centr OUVERTURE PR AMORC E DE 7 PO RONDE RETIRER AUSSI L OUVERTURE PR AMORC E VERTICALE OUVERTURE PR AMORC E VERTICALE DE 3 PO X 10 PO FIGU...

Страница 39: ...TROU POUR C BLE D ALIMENTATION LECTRIQUE B DANS LE DESSOUS DE L ARMOIRE LIGNE DE CENTRE DEVANT DE L ARMOIRE POUR UNE INSTALLATION SOUS UNE ARMOIRE FOND EN RETRAIT UTILISER LES LIGNES POUR MESURER L PA...

Страница 40: ...er l op ration pour l autre c t de l armoire 7 Installer les supports d installation appropri s selon le type d armoire fond en retrait ou fond gal Voir ci dessous 4 Percer un avant trou de 1 8 po de...

Страница 41: ...i re du support contre le mur Tracer une ligne le long du rebord externe du support tel qu il est illustr Glisser le support vers le centre de l armoire et aligner ses c t s ext rieurs sur la ligne tr...

Страница 42: ...ts et accrocher la hotte en utilisant ses 2 TROUS ENFONC S AVANT C et D Tout en retenant la hotte aller l tape 6 5 Accrocher la hotte aux supports par les 2 TROUS ENFONC S AVANT C et D Tout en retenan...

Страница 43: ...s par c t dans les fentes tel qu il est d montr dans les m daillons de l illustration ci dessous 8 Pour une armoire fond gal fixer la hotte l armoire l aide de quatre 4 vis bois t te ronde n 8 x 5 8 p...

Страница 44: ...DE L ARMOIRE TROU POUR CONDUIT VERTICAL VIS DE MONTAGE ARRI RE DE LA HOTTE 2 TROU POUR FIL D ALIMENTATION LECTRIQUE DANS LE DESSOUS DE L ARMOIRE 1 PO CALES DE BOIS SEULEMENT POUR ARMOIRES BASE EN RET...

Страница 45: ...pr c demment Glissez la hotte vers le mur de mani re engager la t te des vis dans la partie troite des trous en forme de serrure du dessus de la hotte Serrer les vis fermement et maintenir la hotte ju...

Страница 46: ...vis VERTE de mise la terre 2 Remettreenplacelecouvercleduventilateur engrisdansl illustrationci dessus l aidedes7vis et de l crou retir s pr c demment l tape 4 en page 10 Porter attention l emplacemen...

Страница 47: ...BLA BLA BLA Transformateur BLA R N Ref 990729478A DEL 2 1 DEL 2 1 BLA R N O V J 1 2 3 5 4 6 BLA R N O V J 1 2 3 5 4 6 N Ligne Neutre Mise la terre 120 V CA M M BR BR BLA C BR BLA C BR N N N N 2 3 J6...

Страница 48: ...CLUANT LES VIS 1 2 S97020534 ADAPTATEUR VOLET DE 3 PO X 10 PO INCLUANT LES VIS 1 1 1 3 S97020412 CONDENSATEUR INCLUANT LES ATTACHES AUTOBLOQUANTES 2 2 2 4 S97020797 AUTOTRANSFORMATEUR AVEC VIS 1 1 1 5...

Страница 49: ...0 SAC DE PI CES COMPRENANT 4 VIS M TAUX N 8 18 X 1 2 PO 6 VIS BOIS T TE RONDE N 8 X 5 8 PO 6 VIS T TE FRAIS E N 8 X 1 2 PO 1 1 1 S97020466 FILTRES DE RECIRCULATION TYPE XC ENSEMBLE DE 2 INSTALLATION S...

Страница 50: ...autres frais de transport pour l envoi du produit ou de la pi ce la Soci t Si vous devez envoyer le produit ou la pi ce la Soci t tel que la Soci t vous l indiquera vous devrez l emballer correctement...