Recommended Tools  and Accessories
for Installation

• Measuring 

tape 

• 

Phillips screwdriver no. 2

• 

Flat blade screwdriver (to open knockout holes)

• 

Drill, 1/8” drill bit and 1½” hole saw (to mark holes for ducting and cut electrical access hole)

• 

7/64” drill bit (to drill holes for EZ1 brackets mounting screws)

• 

7” round duct plate, not included (for 7’’ round vertical ducting installation, part no.: SR680508)

• 

Wood shims (2) and wood screws (4) (required for standard installation to framed cabinet)

• 

Saw (to cut holes for ducted application)

• 

Sheet metal shears (ducted installation only, for duct adjustment)

• 

Pliers (ducted installation only, for duct adjustment)

• 

Metal foil duct tape (for ducted applications)

• 

Scissors (to cut metal foil duct tape)

• Pencil

• Wire 

stripper

• 

Strain relief, 1/2” diameter (to secure house wiring cable to the hood)

Install Ductwork (Ducted Installations Only)

S

OFFIT

18" 

MIN

 - 24" 

MAX

ABOVE

 

COOKING

 

SURFACE

C

ABINET

3¼" 

X

 10" 

DUCT

(F

OR

 

HORIZONTAL

 

DISCHARGE

)

W

ALL

 

CAP

R

OOF

 

CAP

3¼" 

X

 10" 

OR

7" 

ROUND

 

DUCT

(F

OR

 

VERTICAL

DISCHARGE

)

H

OUSE

 

WIRING

(T

OP

 

OR

 

BACK

 

OF

 

HOOD

)

H

OOD

NOTE: Distances over 24” are at the installer and user discretion.

1 ]  

Determine whether hood will discharge vertically (3¼” x 10” or 7” round), 
or horizontally (3¼” x 10” only).

2 ]  

Decide where the ductwork will run between the hood and the outdoors.

3 ]  

Choose a straight, short duct run to allow the hood to perform most efficiently. Long duct 
runs, elbows and transitions will reduce the performance of the hood. Use as few of them as 
possible. When possible, use at least 2-foot straight runs before any turns. Larger ductwork 
may be required for best performance with longer duct runs.

NOTE:  To use 6” round ducting, install a 3¼” x 10” to 6” round transition (not included). The 
   

performances may be affected.

4 ]  

Install wall cap or roof cap (sold separately); ensure there is no leak in house insulation. 
Connect metal ductwork to cap and work back towards the hood location. Use 2” metal foil 
duct tape to seal the joints between ductwork sections.

For ADA compliance installation guidelines, please visit www.broan-nutone.com

Содержание BNDD1 Series

Страница 1: ...Serial number 99045659 001C RANGE HOOD Series BNDD1 INSTALLATION USE AND CARE MANUAL WWW BROAN CA...

Страница 2: ...nstallation 7 19 Recommended Tools and Accessories for Installation 7 Install Ductwork Ducted Installations Only 7 Contents 8 Prepare the Hood 9 11 Prepare the Hood Location 12 EZ1 One Person Installa...

Страница 3: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines a...

Страница 4: ...d you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fi...

Страница 5: ...e desired speed is reached from LOW to MEDIUM to HIGH speed to OFF Each time a blower speed is activated a beep is heard and LED indicators light up to show the corresponding speed chosen lower LED fo...

Страница 6: ...e fan blade should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap o...

Страница 7: ...3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 24 are at the installer and user discreti...

Страница 8: ...DUCTO RECTANGULAR CONDUCTO REDONDO DE 7 PULG O Appuyer ce bord au mur arri re Utiliser ce gabarit pour marquer vos rep res ne pas tenter de d couper le trou pour le conduit travers le gabarit NOTE Les...

Страница 9: ...3 Remove the EZ1 brackets from inside the hood by cutting off the tie wrap Remove both screws holding the damper assembly to the hood Remove the parts bag captured behind the damper assembly Remove t...

Страница 10: ...COVER PLATE SCREWS 6 Remove the Electrical Power Cable Knockout from top vertical wiring or back horizontal wiring of hood Install an appropriate strain relief 1 2 diameter not included 7 Remove the...

Страница 11: ...2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A 7 ROUND DUCT PLATE SCREWS FIG...

Страница 12: ...n retrait utiliser les lignes pour mesurer l paisseur du d calage caus par le mur de l armoire et plier le gabarit en cons quence To be translated in Spanish P C CABINET FRONT C L A B VERTICAL EXHAUST...

Страница 13: ...rews Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at A locati...

Страница 14: ...n the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align the outside edge of the bracket with the marked line keeping the rear end edge leaning on the wall Us...

Страница 15: ...ssed FRONT HOLES C and D While holding the hood attach the power cable to the hood using the strain relief 5 Hang the hood on the brackets using the 2 recessed FRONT HOLES C and D While holding the ho...

Страница 16: ...rts bag Insert 2 screws per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using 4 no 8 x 5 8 round head wood screws included in part...

Страница 17: ...NE HOOD MOUNTING SCREWS 4 ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 7 16 9 24 HOOD 12 30 HOOD 47 16 CABINET BOTTOM 9 24 HOOD 12 30 HOOD 3...

Страница 18: ...crews previously installed Slide hood back towards the wall until mounting screw heads are engaged in the narrow end of keyhole slots in top of hood While holding the hood tighten screws securely Atta...

Страница 19: ...abs on inner top of hood are engaged in their corresponding slots in wiring cover Also make sure not to pinch wires while reinstalling wiring cover 2 Reinstall wiring cover and attach it to the hood u...

Страница 20: ...n back of control board J1 Transformer J2 Power Motor 5 4 3 2 1 5 4 3 2 1 6 7 Control Board R R BL BL BK W BK BK W G Y R Low O Medium BK High W 120 V AC Line Neutral Ground G Y W BK O R FAN MOTOR BN B...

Страница 21: ...STEEL INCL SCREWS 1 1 2 S97020534 3 X 10 DAMPER ASSEMBLY INCLUDING SCREWS 1 1 1 1 3 S97020409 BLOWER MOTOR INCLUDING 4 SCREWS AND 1 CAPACITOR 1 1 1 1 4 S97020407 FANPELLER INCLUDING ITEM 5 1 1 1 1 5...

Страница 22: ...ct or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part...

Отзывы: