background image

INST
ALLA
TION MANUAL

INST
ALLA

TION

19

Connect the Wiring

1 ]  

Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and 
GREEN or bare wire under GREEN ground screw.

!

 WARNING

Risk of electric shock. Electrical wiring must be done by qualifi ed 
personnel in accordance with all applicable codes and standards. 
Before connecting wires, switch power off at service panel and lock 
service disconnecting means to prevent power from being switched 
on accidentally.

!

 CAUTION

Ensure both tabs on inner top of hood are engaged in their corresponding slots in 
wiring cover. Also, make sure not to pinch wires while reinstalling wiring cover.

2 ]  

Reinstall wiring cover and attach it to the hood using its retaining screw.

MOTOR 
GROUND 
WIRE

HOUSE

POWER CABLE

GROUND 
SCREW

Install the Filters

Ducted Installation Only:

Re-install grease filters removed in step 

2

, page 9, under “Prepare the Hood”.

Non-ducted Installation Only:

Purchase two non-ducted filters from your local distributor or retailer (see product specification 
label for filter type). Attach the non-ducted filters following instructions packed with the 
non-ducted filter.

SCREW

TABS ON INNER 
TOP OF HOOD 
ENGAGED IN 
WIRING COVER 
SLOTS.

Содержание BNDD1 Series

Страница 1: ...Serial number 99045659 001C RANGE HOOD Series BNDD1 INSTALLATION USE AND CARE MANUAL WWW BROAN CA...

Страница 2: ...nstallation 7 19 Recommended Tools and Accessories for Installation 7 Install Ductwork Ducted Installations Only 7 Contents 8 Prepare the Hood 9 11 Prepare the Hood Location 12 EZ1 One Person Installa...

Страница 3: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines a...

Страница 4: ...d you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fi...

Страница 5: ...e desired speed is reached from LOW to MEDIUM to HIGH speed to OFF Each time a blower speed is activated a beep is heard and LED indicators light up to show the corresponding speed chosen lower LED fo...

Страница 6: ...e fan blade should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap o...

Страница 7: ...3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 24 are at the installer and user discreti...

Страница 8: ...DUCTO RECTANGULAR CONDUCTO REDONDO DE 7 PULG O Appuyer ce bord au mur arri re Utiliser ce gabarit pour marquer vos rep res ne pas tenter de d couper le trou pour le conduit travers le gabarit NOTE Les...

Страница 9: ...3 Remove the EZ1 brackets from inside the hood by cutting off the tie wrap Remove both screws holding the damper assembly to the hood Remove the parts bag captured behind the damper assembly Remove t...

Страница 10: ...COVER PLATE SCREWS 6 Remove the Electrical Power Cable Knockout from top vertical wiring or back horizontal wiring of hood Install an appropriate strain relief 1 2 diameter not included 7 Remove the...

Страница 11: ...2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A 7 ROUND DUCT PLATE SCREWS FIG...

Страница 12: ...n retrait utiliser les lignes pour mesurer l paisseur du d calage caus par le mur de l armoire et plier le gabarit en cons quence To be translated in Spanish P C CABINET FRONT C L A B VERTICAL EXHAUST...

Страница 13: ...rews Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at A locati...

Страница 14: ...n the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align the outside edge of the bracket with the marked line keeping the rear end edge leaning on the wall Us...

Страница 15: ...ssed FRONT HOLES C and D While holding the hood attach the power cable to the hood using the strain relief 5 Hang the hood on the brackets using the 2 recessed FRONT HOLES C and D While holding the ho...

Страница 16: ...rts bag Insert 2 screws per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using 4 no 8 x 5 8 round head wood screws included in part...

Страница 17: ...NE HOOD MOUNTING SCREWS 4 ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 7 16 9 24 HOOD 12 30 HOOD 47 16 CABINET BOTTOM 9 24 HOOD 12 30 HOOD 3...

Страница 18: ...crews previously installed Slide hood back towards the wall until mounting screw heads are engaged in the narrow end of keyhole slots in top of hood While holding the hood tighten screws securely Atta...

Страница 19: ...abs on inner top of hood are engaged in their corresponding slots in wiring cover Also make sure not to pinch wires while reinstalling wiring cover 2 Reinstall wiring cover and attach it to the hood u...

Страница 20: ...n back of control board J1 Transformer J2 Power Motor 5 4 3 2 1 5 4 3 2 1 6 7 Control Board R R BL BL BK W BK BK W G Y R Low O Medium BK High W 120 V AC Line Neutral Ground G Y W BK O R FAN MOTOR BN B...

Страница 21: ...STEEL INCL SCREWS 1 1 2 S97020534 3 X 10 DAMPER ASSEMBLY INCLUDING SCREWS 1 1 1 1 3 S97020409 BLOWER MOTOR INCLUDING 4 SCREWS AND 1 CAPACITOR 1 1 1 1 4 S97020407 FANPELLER INCLUDING ITEM 5 1 1 1 1 5...

Страница 22: ...ct or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part...

Отзывы: