Страница 1: ...WWW BROAN COM Serial number 99045652 103C WWW BROAN CA RANGE HOOD Series BCDF and BCSEK INSTALLATION USE AND CARE MANUAL...

Страница 2: ...lation 7 20 Recommended Tools and Accessories for Installation 7 Install Ductwork Ducted Installations Only 7 8 Contents 8 Prepare the Hood 9 11 Prepare the Hood Location 12 EZ1 One Person Installatio...

Страница 3: ...cluding fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equ...

Страница 4: ...d you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fi...

Страница 5: ...LOWER BUTTON When blower is OFF press this button to turn ON the blower at the last saved speed If there was no speed saved the blower will be set on LOW speed NOTE When LOW speed is activated from OF...

Страница 6: ...recirculation filters FAN BLADE The fan blade should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soak...

Страница 7: ...UND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 24 are at the installer and user discretion 1 Determine whether hood will discharge vertically 3 x 10 or 7 rou...

Страница 8: ...FIND EZ1 BRACKETS ATTACHED INSIDE OF HOOD 2 GREASE FILTERS 2 GREASE FILTERS 1 3 X 10 DAMPER ASSEMBLY 1 7 ROUND DUCT CONNECTOR 1 PARTS BAG CONTAINING 6 NO 8 X 5 8 RD HD WOOD SCREWS FIND INSIDE OF HOOD...

Страница 9: ...wn and tilting filter s out 3 Remove the EZ1 brackets from inside the hood by cutting off the tie wrap Remove both screws holding damper assembly to hood Remove parts bag captured behind the damper as...

Страница 10: ...Cable Knockout from top vertical exhaust or back horizontal exhaust of hood Install an appropriate strain relief 1 2 diameter not included NON DUCTED INSTALLATION ONLY 2 Remove 3 screws retaining the...

Страница 11: ...plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A...

Страница 12: ...n retrait utiliser les lignes pour mesurer l paisseur du d calage caus par le mur de l armoire et plier le gabarit en cons quence To be translated in Spanish P C CABINET FRONT C L A B VERTICAL EXHAUST...

Страница 13: ...rews Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at A locati...

Страница 14: ...n the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align the outside edge of the bracket with the marked line keeping the rear end edge leaning on the wall Us...

Страница 15: ...ts and hang the hood using its 2 recessed FRONT HOLES C and D While holding the hood attach the power cable to the hood using the strain relief 5 Hang the hood on the brackets using the 2 recessed FRO...

Страница 16: ...ag Insert 2 screws and washers per side in the slots as shown in inset on illustration below 8 For frameless cabinet secure the hood to the cabinet using 4 no 8 x 5 8 round head wood screws screws and...

Страница 17: ...AL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 7 16 47 16 CABINET BOTTOM 12 30 HOOD 15 36 HOOD 18 42 HOOD 12 30 HOOD 15 36 HOOD 18 42 HOOD 3 X 10 VERTI...

Страница 18: ...4 mounting screws previously installed Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely Attach power cable to...

Страница 19: ...bs on inner top of hood are engaged in their corresponding slots in wiring cover Also take care not to pinch wires while reinstalling wiring cover SCREW 2 Reinstall wiring cover and attach it to the h...

Страница 20: ...R BN BN W G Y R Low BK High W 120 V AC Line Neutral Ground BK BK Motor Switch Light Switch BL W W BK BK COLOR CODE BK BL BN BN W BLACK BLUE BROWN BROWN WHITE G Y O R W GREEN YELLOW ORANGE RED WHITE R...

Страница 21: ...on back of control board J1 Transformer J2 Power Motor 5 4 3 2 1 5 4 3 2 1 6 7 Control Board R R BL BL BK W BK BK W G Y R Low O Medium BK High W 120 V AC Line Neutral Ground G Y W BK O R FAN MOTOR BN...

Страница 22: ...SCREWS 1 S97020031 RECIRCULATION COVER PLATE STAINLESS STEEL INCLUDING SCREWS 1 S97020472 RECIRCULATION COVER PLATE SLATE INCLUDING SCREWS 1 2 SR680508 7 ROUND DUCT PLATE INCLUDING SCREWS 1 1 1 1 3 S...

Страница 23: ...ASHERS 4 METAL SCREWS NO 8 18 X 1 2 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK SCREWS 1 1 1 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 S9702046...

Страница 24: ...no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part to the Company If you must send t...