background image

Single Pole (One location)

4-Speed, Quiet,

Ceiling Fan/Light Control

Fan Control

Rating: 1.5A-120VAC, 60Hz

Full Range Dimming

Incandescent Lamp Load

Rating: 300W-120VAC, 60Hz

INSTALLATION INSTRUCTIONS

99042152D

FEATURES

• Controls a dimmer and fan in a single gang wall

box

• Four Preset fan levels
• Full range rotary dimming
• Ideal for any area where ceiling fan noise is

distracting

INSTALLATION INSTRUCTIONS

WARNING:

 TO BE INSTALLED AND/OR USED

IN ACCORDANCE WITH APPROPRIATE
ELECTRICAL CODES AND REGULATIONS.

WARNING: 

IF YOU ARE NOT SURE ABOUT

ANY PART OF THESE INSTRUCTIONS,
CONSULT A QUALIFIED ELECTRICIAN.

WARNING: 

TO AVOID OVERHEATING AND

POSSIBLE DAMAGE TO THIS DEVICE AND
OTHER EQUIPMENT, DO NOT INSTALL TO
CONTROL A RECEPTACLE, FLUORESCENT
LIGHTING, A MOTOR- OR A TRANSFORMER-
OPERATED APPLIANCE OTHER THAN
APPROPRIATE CEILING FANS AND
INCANDESCENT LAMPS.

WARNING: 

TO REDUCE THE RISK OF FIRE

OR ELECTRICAL SHOCK, THIS CONTROL IS
TO BE USED WITH CEILING FANS THAT ARE
MARKED AS SUITABLE FOR USE WITH A
SOLID-STATE FAN SPEED CONTROL AND IS
RATED 120 VOLTS AC, TOTAL LOAD 1.5
AMPERES MAXIMUM.

WARNING:

 FOR USE ON CEILING PADDLE

FANS WITH SPLIT-CAPACITOR OR SHADED
POLE MOTORS ONLY. PLEASE REFER TO
FAN MANUFACTURER’S INSTRUCTIONS OR
RATING LABEL ON THE MOTOR TO CONFIRM
TYPE. USE WITH ANY OTHER TYPES OF
MOTORS OR EQUIPMENT MAY CAUSE
OVERHEATING AND/OR DAMAGE TO THE
MOTORS OR EQUIPMENT.

OTHER CAUTIONS:
1.

USE ONLY ONE (1) SPEED CONTROL PER
LOAD.

2.

DISCONNECT POWER WHEN SERVICING
FIXTURE.

3.

USE THIS DEVICE ONLY WITH COPPER OR
COPPER CLAD WIRE. WITH ALUMINUM
WIRE USE ONLY DEVICES MARKED CO/
ALR OR CU/AL.

MULTI-FAN CONTROL:

Any number of fans of the same type may be
controlled by a single fan speed control provided
that the total amperage of the fans do not exceed
the amperage of the fan speed control.

MULTI-GANG INSTALLATION:

There is NO derating necessary for multi-gang
installations of this Quiet Fan/Light Control.

TO INSTALL:
1. WARNING: 

TO AVOID FIRE, SHOCK, OR

DEATH; TURN OFF POWER AT CIRCUIT
BREAKER OR FUSE AND TEST THAT
POWER IS OFF BEFORE WIRING!

2.

Remove existing wallplate and switch, if
applicable.

3.

Remove 3/4" (1.9 cm) of insulation from each
circuit conductor. Make sure the ends of wires
are straight.

WIRE CONNECTOR / # OF CONDUCTOR COMBINATION CHART

1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 #14 w/ 1 #16 or #18
2- #12 w/ 1 #16 w/ 1 or 2 #18
2- #14 w/ 1 to 3 #16, #18 or #20
4- #16 w/ 1 or 2 #18, #20 or #22
1- #14 w/ 1 to 4 #16, #18 or #20
2- #14 w/ 1 to 3 #16, #18 or #20

2- #14 w/ 1 #16 w/ 1 or 2 #18 or #20
3- #14 w/ 1 or 2 #18 or #20
4- #14 w/ 1 #16 or #18
2- #16 w/ 1 #18 w/ 1 or 2 #20 or #22
1- #14 w/ 1 #18 w/ 1 to 3 #20
3- #14 w/ 1 #16 w/ 1 #18, #20, #22
3- #14 w/ 1 #18 w/ 1 #20 or #22

O

F

F

M

A

X

HI

ME

D

MODEL

79V / 79W

BROAN-NUTONE ONE YEAR LIMITED WARRANTY

Broan-NuTone warrants to the original consumer purchaser of its
products that such products will be free from defects in materials or
workmanship for a period of one year from the date of original
purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRAN-
TIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or
replace, without charge, any product or part which is found to be
defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal
maintenance and service or (b) any products or parts which have been
subject to misuse, negligence, accident, improper maintenance or
repair (other than by Broan-Nutone), faulty installation or installation
contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period
as specified for the express warranty. Some states do not allow
limitation on how long an implied warranty lasts, so the above limitation
may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT
BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-
NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUEN-
TIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNEC-
TION WITH PRODUCT USE OR PERFORMANCE. Some states do
not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have
other rights, which vary from state to state. This warranty supersedes
all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at
the address or telephone number below, (b) give the model number
and part identification and (c) describe the nature of any defect in the
product or part. At the time of requesting warranty service, you must
present evidence of the original purchase date.

Broan-NuTone LLC, 

 926 West State Street, Hartford, WI 53027

(1-800-637-1453)

Rotary

ON/OFF

Fan Speed

Rotary

ON/OFF
Dimmer

Mounting 

Strap

F

F

L

O

ME

D

MAX

HI

Figure 1 - Fan Speed Control Functions

Hot (Black)

Neutral (White)

Fan

Light

Fan Speed/Dimmer

Black

Green

Ground

Black

Black

White

White

Red (Motor) Hot

Yellow (Light) Hot

Line 

120VAC, 60Hz

O

F

F

M

AX

HI M

ED

L

O

Wiring Diagram 1 - Single Location Control Application

4.

Connect wires per appropriate WIRING
DIAGRAM as follows: Twist strands of each
lead tightly and, with circuit conductors, push
firmly into appropriate wire connector. Screw
connectors on clockwise making sure no bare
wires show below the wire connectors. Secure
each connector with electrical tape.

5.

Installation may now be completed by carefully
positioning all wires to provide room in outlet
box for control. Mount control into box with
mounting screws supplied. Attach wallplate.

6.

Restore power at circuit breaker or fuse.
Check for proper operation as follows:

Dimmer:

Rotate top knob control clockwise and counter-
clockwise and ensure that the lights DIM or
BRIGHTEN accordingly.

Fan Speed:

Position the bottom knob to each of the four
levels: MAX, HIGH, MEDIUM and LOW 

(refer

Figure 1)

. Ensure that fan speed changes

accordingly.

7. INSTALLATION IS COMPLETE.

TO OPERATE

Dimmer:

• Rotate top knob control clockwise

- Lights will BRIGHTEN accordingly

• Rotate top knob control counter-clockwise

- Lights will DIM accordingly

• Rotate top knob control fully counter-clockwise

- Lights will turn OFF

Fan Speed:

• Rotate bottom knob control to each of the four

levels; MAX, HIGH, MEDIUM, and LOW

- Fan will increase or decrease in speed

respectively for desired level.

• Rotate knob control to OFF position

- Fan will turn OFF.

TROUBLESHOOTING

• Fan does not turn ON or does not run

Multispeed
- Circuit breaker or fuse has tripped.
- Fan is not connected to line Neutral.
- Switch on Fan not set to HIGH position.
- Fan and light miswired.

• Light does not turn ON

- Circuit breaker or fuse has tripped.
- Bulb has burned out.
- Lamp is not connected to line Neutral.
- Switch on Fan unit controlling Light is not in

the ON position (if applicable).

- Fan and light miswired.

Отзывы: