background image

1

READ  AND SAVE THESE INSTRUCTIONS

MODELS 165F AND 167F
FAN FORCED WALL HEATERS
FINISH ASSEMBLIES

FOR USE WITH BROAN MODEL 171H ROUGH-IN HOUSING

PLANNING

This wall heater finish assembly is intended for installation into a 

Broan Model 171H rough-in housing — after the wall has been 

completed.
The heater can be operated using the Broan Model 86 Line-

Voltage Thermostat from a wall location or the Broan Model 83 

Integral Thermostat installed into heater. Purchase the control 

separately.

The table below lists the ratings for each model.

 MODELS  VOLTS  AMPS 

WATTS 

BTU/HR

 

165F 120 4.17 

500 

1707

  

240 2.08 

500 

1707

  

208  1.8 

375 

1280

 167F 

240 3.13/

6.25

 750/

1500

 2560/

5120

 

 

208 2.71/5.41 563/1125  1922/3840

  

BOLD

 ratings are factory wired. See "OPTIONAL WIRING 

CONVERSIONS" section for wattage and voltage conversion 

instructions.

Follow these basic steps when installing this heater:

•  Remove the housing mask.
•  Fasten finish assembly inside housing.
•  Plug assembly in.
•  Attach grille.

HEATER

HOUSING

POWER 

CABLE

DRYWALL

GRILLE

HEATER

HOUSING

WALL
STUD

IMPORTANT INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE 

INSTALLING OR USING THIS  HEATER.

To reduce the risk of fire, electric shock, or injury to persons, observe 

the following:
1. Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address or 

telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service panel 

and  lock  the  service  disconnecting  means  to  prevent  power  from 

being switched on accidentally. When the service disconnecting 

means  cannot  be  locked,  securely  fasten  a  prominent  warning 

device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qualified 

person(s)  in  accordance  with  all  applicable  codes  and  standards, 

including fire-rated construction codes and standards.

4.  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

5.  This heater is hot when in use. To avoid burns, do not let bare skin 

touch hot surfaces. Keep combustible materials, such as furniture, 

pillows, bedding, papers, clothes, etc. and curtains at least 3 feet (0.9 

m) from the front of the heater.

6. Extreme caution is necessary when any heater is used by or near 

children or invalids and whenever the heater is left operating and 

unattended.

7. Do not operate any heater after it malfunctions. Disconnect 

power at service panel and have heater inspected by a reputable 

electrician before reusing.

8.  Do not use outdoors.

9.  To  disconnect  heater,  turn  controls  to  off,  and  turn  off  power  to 

heater circuit at main disconnect panel (or operate internal 

disconnect switch, if provided).

10. Do not insert or allow foreign objects to enter any ventilation or 

exhaust opening, as this may cause an electric shock or fire, or 

damage the heater.

11.  To prevent a possible fire, do not block air intakes or exhaust in 

any manner.

12. A heater has hot and arcing or sparking parts inside. Do not use it 

in areas where gasoline, paint, or flammable vapors or liquids are 

used or stored.

13. Use this heater only as described in this manual. Any other use 

not recommended by the manufacturer may cause fire, electric 

shock, or injury to persons.

14. Install heater at least 6 inches from floor or any adjacent wall.
15. To  avoid  electrical  shock:  Do  not  install  unit  in  a  tub  or  shower 

enclosure or any location where it may come in contact with water. 

Never place a switch where it can be reached from a tub or shower.

16. This product may ONLY be installed horizontally in a wall. Do not 

mount in any other position.

17.  Do not connect heater to dimmer switch or speed control.
18. This product must be grounded.

SAVE THESE INSTRUCTIONS

Содержание 165F

Страница 1: ... s in accordance with all applicable codes and standards including fire rated construction codes and standards 4 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 5 This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Keep combustible materials such as furniture pillows bedding papers clothes etc and curtains a...

Страница 2: ...mbly has no adjustable thermostat control If a wall mounted control has been pre wired nothing else need be done If a built in thermostat is desired purchase and insert the Broan Model 83 Integral Thermostat at this time 2 Install heater assembly into housing BLACK WIRE from motor WHITE WIRES 2 BLACK WIRES connected to motor 2 WHITE WIRES Installation work and electrical wiring must be done by a q...

Страница 3: ...F MODEL 167F 1 Conversion to full wattage The heater will produce more heat and use more electricity if converted to full wattage Connect the unattached black wire with the insulated terminal to motor terminal UNATTACHED BLACK WIRE MOTOR TERMINAL ...

Страница 4: ...to heater with two 2 screws from parts bag 2 Check operation Turn on power at service entrance Turn thermostat to its highest setting and make sure heating element and blower come on Then turn it to its lowest setting and make sure element and blower shut off ...

Страница 5: ...5 OPERATION Before using heater make sure heater has been properly installed according to installation steps beginning with the PLANNING section on page 1 ...

Страница 6: ...stat is turned to its highest setting Turn power off at service entrance Remove knob and grille and press button marked RESET LUBRICATION The heater is permanently lubricated and never needs oiling or disassembly CLEANING Clean heater once a month as follows 1 Turn off power at service panel 2 Make sure heating element is cool 3 Use a soft brush attachment to gently vacuum grille open ings or wipe...

Страница 7: ... duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE...

Страница 8: ... 99045021A KEY PART NO NUMBER DESCRIPTION 1 97008681 Housing 2 98003036 Mounting Bracket 2 Required 3 99260512 8 18 Sheet Metal Nut 2 Required 4 99390015 Grounding Clip 5 97005422 Receptacle Assembly 6 98006975 Wiring Cover 7 99020130 Blower Wheel 8 99080248 Motor Model 165F 99080276 Motor Model 167F 9 99270735 Tab Adapter 10 99030194 Thermal Overload 11 99271091 Guard 12 98006974 Element Bracket ...