Overture
TM
SMART PLUG
INCLUDED
Smart Plug Part No. 1103436
User Manual
Quick Start Guide
1103417A
For Warranty Statement, Service Parts, Technical
Support, or to Register your product, please visit our
website or call: In the United States - Broan-NuTone.com
800-558-1711. In Canada - Broan.ca or NuTone.ca
877-896-1119
CONTROL SPECIFICATIONS
• cULus
Listed
• 120 VAC 60 Hz Line Power
• Requires NEMA 5-15R or 5-20R Receptacle
• Maximum load 15A Resistive, 15A Inductive, ½ HP
Motor, 3A Incandescent
• Dry Contact Class 2 - 24VAC, 60Hz or 12VDC, 40VA
Max Load
• Operating temperature: 32-95°F (0-35°C)
• Purpose of Control: Operating Control
• Rated impulse voltage: 1500 V
SAFETY
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Before installing and connecting the Smart Plug,
switch power off at the service panel and lock the
service disconnecting means to prevent power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel. CAUTION: Risk of Electric Shock - More than
one disconnect switch may be required to de-energize
the equipment before servicing.
2. All electrical work must be done in accordance with
local codes, ordinances, or National Electrical Code,
as applicable, including fire-rated construction
codes and standards. FOR SAFETY, THIS PRODUCT
MUST BE GROUNDED. If you are unfamiliar with
methods of installing electrical wiring, secure the
services of a qualified electrician.
3. Use copper wire only.
4. When cutting or drilling into wall or ceiling, do not
damage electrical wiring or other hidden utilities.
5. To prevent serious injury from electrical shock or
damage to electrical components - DO NOT WIRE
HOT!
6. Install only in a UL Listed NEMA 5-15R or NEMA
5-20R receptacle. The socket-outlet shall be
installed near the equipment and shall be easily
accessible. a. NOTE: This device shall not be
used in combination with a wall switch controlled
receptacle.
7. The automatic operation feature is Type 1 action,
according to UL 60730-1.
8. The enclosure protection rating is IP20.
9. The product is Pollution Degree 2, which is intended
to be used in a household environment or similar.
10. The devices are not intended for use in locations
where the temperature may be less than actual
room conditions, such as unheated warehouses or
garages.
11. Avoid water and wet locations. Keep the device
away from water, fire, excessive humidity, or hot
environments.
12. Do not use the device where wireless devices are
not allowed.
13. For passthrough devices, plug the power strips into
the integrated electrical sockets of the devices, but
devices of the same or another type not be stacked
in normal use.
14. Do not attempt to disassemble, repair, or modify
the device. Don’t disassemble the product, or
make repairs yourself. You run the risk of electric
shock and voiding the limited warranty. If you need
service, please contact us.
HRV/ERV INSTALLATION
1. Turn off the power and lockout the service panel before
wiring the control to your Fresh Air System.
2. Verify Smart Plug orientation before installation.
Note “TOP” direction shown on the Smart Plug
label.
3. Location Notes:
a. Place your Smart Plug within the range of your
Wi-Fi router or access point (approximately 100
feet).
b. Avoid physical obstructions and radio
interference in the surrounding area.
4. Make electrical connections following the diagrams
provided below and in the Broan-NuTone Overture
TM
App using appropriate wiring for the application.
Use wire nuts. Make sure both the Smart Plug and
the Fresh Air System are properly grounded. Wire
terminals accept #20 AWG to #16 AWG solid or
stranded wire suitable for at least 75°C.
a. Strip wire to 0.5
"
length, press the wire release
mechanism, and insert the bare wire into the screw
terminal opening. Make sure the wire is seated as
far into the terminal is possible.
b. Release the wire release mechanism making sure
wire remains under the clamp.
c. Note: Do not reuse wire formed into a “J” loop or
wrapped around screw threads. The wire terminal is
designed for the straight insertion of stripped wire
for proper mechanical and electrical connection.
5. Route wires to HRV/ERV.
Regulatory Information
The Overture
TM
Smart Plug 1103436 is certified to comply
with applicable FCC and IC rules and regulations governing
RF and EMI emissions. Refer to 1103436. This device
complies with Part 15 of the FCC Rules. Operation is sub-
ject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must
accept any interference received, including interference
that may cause undesired operation.
FCC Notice
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV
technician to help.
Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
ISED Compliance Statement
This device contains licence-exempt transmitter(s)/
receiver(s) that comply with Innovation, Science and
Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including
interference that may cause undesired operation of the
device.
The Bluetooth® word mark and logos are registered
trademarks owned by Bluetooth SIG, Inc. and any use
of such marks by Broan-NuTone LLC is under license.
Other trademarks and trade names are those of their
respective owners.
The Android robot is reproduced or modified from work
created and shared by Google and used according to
terms described in the Creative Commons 3.0 Attribution
License.
Regulatory ID for 1103436 Overture
TM
Smart Plug
FCC ID: 2ADLL-1103436
IC: 2143B-1103436
M a d e i n C h i n a t o t h e q u a l i t y s t a n d a r d s a n d
specifications of
Broan-Nutone LLC Hartford, Wisconsin
www.broan-nutone.com 800-558-1711
Venmar Ventilation ULC Drummondville Quebec Canada
www.broan.ca or www.nutone.ca 877-896-1119
For more information and user manuals scan QR code
below.
15. Note: When power is applied, the Smart Plug may
require approximately 30 seconds to boot up and be
ready to function.
16. Please read and follow the above safety
information when operating the device. We cannot
guarantee that no accidents or damage will occur
due to the improper use of the device. Please use
this product with care and operate at your own risk.
Warranty is void if miswired.
BIAQSP100P
Overture Smart Plug
Class II Wiring
BIAQSP100P
Overture
TM
Smart Plug
Class 2 Wiring
HRV/ERV
Smart Plug With HRV/ERV
OC
OL
SUPPLY FAN/MAKE UP AIR DAMPER
INSTALLATION
1. For supply fan and make up air damper installation,
plug the power cord into the Smart Plug receptacle.
2. Download the Broan-NuTone Overture
TM
App for
step by step set-up instructions to connect your
Smart Plug to the Overture
TM
system. Scan QR code
to go to App Store.
1103417_A.indd 1
2020-11-24 10:37:00
The distance between user and products should be no less than 20cm
The distance between user and products should be no less than 20cm