background image

 

 

DiViNe Route 66

 

4 / 18 

rev. 1.2 

  

 

 Power Supply 

The  device  can  be  disconnected  from  the  power  supply  by  pulling  the  plug.  These  must  be  freely 
accessible at all times. The device should be disconnected during lightning storms or when unused 
for long periods of time. The switched-mode power supplies operate with very high voltages. Coming 
into contact with them can lead to considerable electric shock, which may result in death. 

Never disconnect the main plug by pulling the cable, always pull the plug itself. 

Power-supply cords should be routed in such a way that they are not likely to be walked on, crushed, 
pinched,  or  damaged  in  any  other  way.  Pay  special  attention  to  the  plugs  and  the  sockets  of  the 
device. 

Replace a damaged power cable immediately. 

The  device  must  be  grounded;  any  disconnection  of  the  grounding  is  not  permitted.  Always  ensure 
the correct grounding of the device via the main plug. Never cover the grounding terminal of the plug 
by means of insulation material! 

 

Fuse 

There exists no fuse inside the device. The power supplies are protected for overload conditions due 
to their circuitry.  

 

Lightning 

For  additional  protection  of  this  device  during  lightning  storms,  or  when  it  is  left  unattended  and 
unused for a long period of time, unplug the power cord. This will prevent damage to the device due 
to lightning and power line surges. Disconnection from the mains power supply can only be achieved 
by removing the plug from the mains socket. 

 

Interference by means of external objects and/or liquids with the device 

Never push objects of any kind into the device through openings in the casing. They may come into 
contact with dangerous voltage points or short out parts that could result in a fire or electric shock. 
Never spill liquid of any kind on the device. 

 

Cables and Accessories 

Only use attachments specified by the manufacturer. 

Only  use  high  quality  cable  to  connect  the  device.  For  the  optical  data  connection,  you  should 
exclusively  use  the  specified  optical  waveguide  cables.  If  not  in  use,  ensure  that  the  optical 
connectors of both the device and waveguide are covered with the provided caps. 

Do not place this device on an unstable table, tripod, cart, etc. The device may fall, which can cause 
injury and serious damage to the device. Any mounting of the device should follow the manufacturer’s 
instructions, and should use mounting accessories recommended by the manufacturer. 

 

Servicing 

Do not attempt to service this device yourself. 

This device contains no user serviceable parts: only refer to authorised, qualified service personnel 
for any servicing. 

The opening of the device is not required for operation as there are no user serviceable components 
located inside the device. The operation of an opened device is not permitted. It can lead to damage 
of components due to the absence of required ventilation. The device may not be serviced, altered or 
modified  without  authorisation  from  BroaMan  or  an  BroaMan  authorised  distributor  /  dealer.  Only 
qualified service personnel may carry out repair and maintenance work. The warranty will be voided if 
unauthorised maintenance has occurred

.

Содержание DiViNe Route 66

Страница 1: ...ideo Network Operating Manual Rev 1 2 Operating Manual for DiViNe Route 66 Digital Video Network device with Optocore and SANE Copyright 2017 All rights reserved BROAMAN GmbH Lohenstr 8 82166 Munich Gräfelfing Germany ...

Страница 2: ... the power cord from being stepped on crushed pinched or damaged in any other way Pay special attention to plugs and sockets of the device Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device The device can be disconnected from the power supply by pulling the plug These must be freely accessible at all times The device should be dis...

Страница 3: ... and entertainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for use in moderate climates Ventilation Do not block or cover any ventilation slits Install the device in accordance with the operating manual Leave sufficient venti...

Страница 4: ... Interference by means of external objects and or liquids with the device Never push objects of any kind into the device through openings in the casing They may come into contact with dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the device Cables and Accessories Only use attachments specified by the manufacturer Only us...

Страница 5: ...ful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to c...

Страница 6: ...k 11 Transmission Delay 11 Power Supply 11 Control 12 Connectors and Cables 12 Optical Connection 12 SD HD 3G Ports 12 SANE Ports 12 Auxiliary Ports 12 RS232 Connection 12 Connector Hood Quality 12 USB Connection 12 LAN Connection 12 Word Clock Connection 12 Mains Connection 12 Connection Example 13 Connection Tables 14 Technical Specifications 15 Dimensions and Weight 16 Warranty and Liability 17...

Страница 7: ...tical fiber Every single Route 66 product is different and customised to meet even the most sophisticated requirements Route board is capable of handling up to 66 video channels Each Route66 is being delivered in 2RU frame which is equipped with up to 24 BNC ports for SD HD 3G video 20 duplex LC fiber ports and additionally up to 36 simplex LC fiber ports Additionally Route 66 is equipped with sta...

Страница 8: ...munication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel OL1 Communication is established via Optocore LINK 1 rear panel OL2 Communication is established via Optocore LINK 2 rear panel Master LED Indicates the master unit OPTO LED Optocore communication is established SANE LED SANE communication is established Device ID Display Indicates the identifica...

Страница 9: ...anel S2 Ethernet communication is established via SANE 2 rear panel UP There is other device with physical Ethernet port enabled on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Ethernet communication is established via LAN 2 rear panel POWER MUTE Mic Card Phantom Power Output Card Mute Sample rate LED Yellow 44 1 48 88 2 96 176 4 192 kHz ...

Страница 10: ...SFP fiber ports with TX and RX Each port can be configured by manufacturer as Video Link or Optocore Link for Optocore Router Word Clock IN BNC Word clock input allows synchronization of Optocore devices to an external word clock source Word Clock OUT BNC Word clock output for synchronization of external devices SANE 1 SANE RJ 45 interface for data transmission 100 Mbit Ethernet SANE 2 SANE RJ 45 ...

Страница 11: ... control data OPTOCORE CONTROL software is used for setting the destination of each interface Word Clock All units are equipped with a Word Clock IN and OUT Word Clock is also transmitted via the fiber and SANE Ports In network configurations no extra BNC cable is needed The X6R V3R FX INTERCOM units are equipped with an internal high quality and extremely low jitter word clock Any X6R V3R FX INTE...

Страница 12: ...e available along with matching inter connection cables transported on cable drums Please refer to Product Brochure available at www BroaMan com SD HD 3G Ports Coaxial 75 Ω cable with BNC connectors compliant with digital SD HD 3G standard can be used The maximum distance is 300 m SANE Ports Use standard twisted 4 pair cable Cat 5 Cat 5e Cat 6 with RJ 45 connectors SANE technology utilises all 4 p...

Страница 13: ... each locations it is possible to connect Repet48WDM unit which is equipped with two SD HD 3G outputs four inputs and two fiber optic tunnels for OPTOCORE protocol transport Connections between Route66 and both Repeat48WDM are done by fiber cables Routing in Route66 platform may be set to the fixed layout or be controlled by user with a controlling software platform like VSM Fig 1 Connection of on...

Страница 14: ... 2 3 4 Pin 1 2 3 4 5 6 7 8 9 D Sub 9 female Error Not a valid embedded object Locking system acc to 4 40 UNC Pin out RS232 Port Channel RS232 Internally bridged Power Use standard RS232 cable male female to connect to PC RXD TXD 5VS GND Pin 3 2 1 4 6 7 8 9 5 D Sub 9 female Error Not a valid embedded object Locking system acc to 4 40 UNC Pin out USB Port Channel USB GND USB device connector VBUS D ...

Страница 15: ...92 kHz Impedance Output 5 Ω Input 75 Ω Drive level Output 1 Vpp Zero level Referring to GND 1 7 V Sense level Input 400 mVpp Remote Control Convention RS232 EIA TIA 232 57 600 Baud USB USB 2 0 Device 12 Mbit s LAN IEEE 802 3 10 100 Mbit s Power supply Type Switch mode universal input Mains voltage 100 240 V Frequency 50 60 Hz Power consumption Depending on device 32VA Max Security classification C...

Страница 16: ...46 inch 2RU frame 44 mm 1 73 inch 1RU frame depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight Dependent on components and port configuration of each specific device Modifications that serve the purpose of technical improvement of the device may be carried out without prior notification ...

Страница 17: ...distributors dealers Always ensure the careful handling of the device If possible these devices should always be transported or shipped in special shock absorbing transport cases If these are not available we recommend well padded packaging such as the coated carton in which the device was delivered We strongly advise not to use simple flight cases without rack in rack mounting Declaration of Liab...

Страница 18: ...iNe Route 66 18 18 rev 1 2 Company Information Mailing Address BROAMAN GmbH Lohenstr 8 D 82166 Munich Gräfelfing Germany Telephone 49 0 89 8999640 Facsimile 49 0 89 89996455 Internet www BroaMan com Email ...

Отзывы: