95
SYSTEM CVs
CV122
Consist Functions Type 3
Description
Determines Which Functions (
) are allowed in the Consist
Values
0-255
Initial Value
255
Related CVs
Bit 7
Bit 0
F28 F27 F26 F25 F24 F23 F22 F21
The decoder responds to all functions that have a “1” set in this CV
once a consist is configured. A consist is configured by CV19
programmed to a value from 1-127. A value of 0 breaks the consist.
See CV19. This CV is used to configure the engine for a front, middle
or end in the consist.
An example for consist number 60:
CV19=60
Front Engine CV21=255 CV22=255 CV121=255 CV122=255 CV229=246
Middle Engine CV21=176 CV22=5 CV121=0 CV122=96
CV229=0
Rear engine CV21=176 CV22=5 CV121=0 CV122=96
CV229=2